PACIO Advance Directive Interoperability Implementation Guide
1.0.0 - STU 1 United States of America flag

This page is part of the PACIO Advance Directive Information Implementation Guide (v1.0.0: STU 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

: Documentation Types - JSON Representation

Active as of 2024-01-11

Raw json | Download


{
  "resourceType" : "ValueSet",
  "id" : "ADIDocumentationTypeVS",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This value set includes codes based on the following rules:</p><ul><li>Include these codes as defined in <a href=\"http://loinc.org\"><code>http://loinc.org</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"https://loinc.org/81352-7/\">81352-7</a></td><td>Medical Order for Life-Sustaining Treatment, Physician Order for Life-Sustaining Treatment, or a similar medical order is in place [Reported]</td></tr><tr><td><a href=\"https://loinc.org/81351-9/\">81351-9</a></td><td>Do Not Resuscitate, Do Not Attempt Resuscitation, or Allow Natural Death order is in place [Reported]</td></tr><tr><td><a href=\"https://loinc.org/42348-3/\">42348-3</a></td><td>Advance directives</td></tr></table></li><li>Include these codes as defined in <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"http://snomed.info/id/304253006\">304253006</a></td><td>Not for resuscitation</td></tr><tr><td><a href=\"http://snomed.info/id/714748000\">714748000</a></td><td>Has advance care plan</td></tr></table></li><li>Include codes from <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a> where concept  is-a  425392003 (Active advance directive (finding))</li><li>Include codes from <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a> where concept  is-a  423876004 (Clinical document (record artifact))</li></ul></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "pe"
    }
  ],
  "url" : "http://hl7.org/fhir/us/pacio-adi/ValueSet/ADIDocumentationTypeVS",
  "version" : "1.0.0",
  "name" : "ADIDocumentationTypeVS",
  "title" : "Documentation Types",
  "status" : "active",
  "experimental" : false,
  "date" : "2024-01-11T18:07:17+00:00",
  "publisher" : "HL7 International / Patient Empowerment",
  "contact" : [
    {
      "name" : "HL7 International / Patient Empowerment",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/patientempowerment"
        },
        {
          "system" : "email",
          "value" : "patients@lists.HL7.org"
        }
      ]
    }
  ],
  "description" : "Types of Documents",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "US"
        }
      ]
    }
  ],
  "copyright" : "This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc\n\nThis value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement",
  "compose" : {
    "include" : [
      {
        "system" : "http://loinc.org",
        "concept" : [
          {
            "code" : "81352-7",
            "display" : "Medical Order for Life-Sustaining Treatment, Physician Order for Life-Sustaining Treatment, or a similar medical order is in place [Reported]"
          },
          {
            "code" : "81351-9",
            "display" : "Do Not Resuscitate, Do Not Attempt Resuscitation, or Allow Natural Death order is in place [Reported]"
          },
          {
            "code" : "42348-3",
            "display" : "Advance directives"
          }
        ]
      },
      {
        "system" : "http://snomed.info/sct",
        "concept" : [
          {
            "code" : "304253006",
            "display" : "Not for resuscitation"
          },
          {
            "code" : "714748000",
            "display" : "Has advance care plan"
          }
        ]
      },
      {
        "system" : "http://snomed.info/sct",
        "filter" : [
          {
            "property" : "concept",
            "op" : "is-a",
            "value" : "425392003"
          }
        ]
      },
      {
        "system" : "http://snomed.info/sct",
        "filter" : [
          {
            "property" : "concept",
            "op" : "is-a",
            "value" : "423876004"
          }
        ]
      }
    ]
  }
}