Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-regional-nodes-category' |
Error | StructureDefinition.version | Values for version differ: '3.2.0' vs '1.16.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreLaboratoryResultObservationProfile' vs 'TNMRegionalNodesCategory' |
Information | StructureDefinition.title | Values for title differ: 'US Core Laboratory Result Observation Profile' vs 'TNM Regional Nodes Category' |
Information | StructureDefinition.date | Values for date differ: '2020-06-27' vs '2021-04-15T12:44:45+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International Clinical Interoperability Council' |
Warning | Observation | Elements differ in definition:
'This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Laboratory Test Name'
'Type of observation (code / type)' |
Warning | Observation.code | Elements differ in definition:
'The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC.'
'Describes what was observed. Sometimes this is called the observation 'name'.' |
Warning | Observation.code | Elements differ in comments:
'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.'
'*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' |
Error | Observation.focus | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.effective[x] | Elements differ in definition:
'For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Warning | Observation.value[x] | Elements differ in short:
'Result Value'
'Actual result' |
Warning | Observation.value[x] | Elements differ in definition:
'The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Error | Observation.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.method | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.device | Elements differ in short:
'(Measurement) Device'
'Not used in this profile' |
Warning | Observation.device | Elements differ in definition:
'The device used to generate the observation data.'
'Not used in this profile' |
Warning | Observation.referenceRange | Elements differ in short:
'Provides guide for interpretation'
'Not used in this profile' |
Warning | Observation.referenceRange | Elements differ in definition:
'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.'
'Not used in this profile' |
Warning | Observation.hasMember | Elements differ in short:
'Related resource that belongs to the Observation group'
'Not used in this profile' |
Warning | Observation.hasMember | Elements differ in definition:
'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
'Not used in this profile' |
Warning | Observation.component | Elements differ in short:
'Component results'
'Not used in this profile' |
Warning | Observation.component | Elements differ in definition:
'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
'Not used in this profile' |