Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab vs http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status

Left:US Core Laboratory Result Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab)
Right:Karnofsky Performance Status (http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status'
ErrorStructureDefinition.versionValues for version differ: '3.2.0' vs '1.16.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreLaboratoryResultObservationProfile' vs 'KarnofskyPerformanceStatus'
InformationStructureDefinition.titleValues for title differ: 'US Core Laboratory Result Observation Profile' vs 'Karnofsky Performance Status'
InformationStructureDefinition.dateValues for date differ: '2020-06-27' vs '2021-04-15T12:44:45+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International Clinical Interoperability Council'
WarningObservationElements differ in definition: 'This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements.' 'Measurements and simple assertions made about a patient, device or other subject.'
ErrorObservation.basedOnType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan], CanonicalType[http://hl7.org/fhir/StructureDefinition/DeviceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/NutritionOrder], CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan]])
ErrorObservation.partOfType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationAdministration], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationDispense], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationStatement], CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure], CanonicalType[http://hl7.org/fhir/StructureDefinition/Immunization], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure]])
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Laboratory Test Name' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in binding.description: 'LOINC codes' 'Codes identifying names of simple observations.'
WarningObservation.effective[x]Elements differ in definition: 'For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
WarningObservation.value[x]Elements differ in short: 'Result Value' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification.' 'The information determined as a result of making the observation, if the information has a simple value.'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.interpretationElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.interpretationUnable to resolve right value set http://loinc.org/vs/LL4986-7 at Observation.interpretation
WarningObservation.bodySiteElements differ in short: 'Observed body part' 'Not used in this profile'
WarningObservation.bodySiteElements differ in definition: 'Indicates the site on the subject's body where the observation was made (i.e. the target site).' 'Not used in this profile'
WarningObservation.specimenElements differ in short: 'Specimen used for this observation' 'Not used in this profile'
WarningObservation.specimenElements differ in definition: 'The specimen that was used when this observation was made.' 'Not used in this profile'
WarningObservation.deviceElements differ in short: '(Measurement) Device' 'Not used in this profile'
WarningObservation.deviceElements differ in definition: 'The device used to generate the observation data.' 'Not used in this profile'
WarningObservation.hasMemberElements differ in short: 'Related resource that belongs to the Observation group' 'Not used in this profile'
WarningObservation.hasMemberElements differ in definition: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' 'Not used in this profile'
WarningObservation.componentElements differ in short: 'Component results' 'Not used in this profile'
WarningObservation.componentElements differ in definition: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' 'Not used in this profile'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observation
      .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
      • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
      .date2020-06-272021-04-15T12:44:45+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve laboratory test resultsThe Karnofsky Performance Status (KPS) is a tool used to measure a patient's functional status. It can be used to compare the effectiveness of different therapies and to help assess the prognosis of certain patients, such as those with certain cancers. The KPS score ranges from 0 to 100 in intervals of 10. Higher scores are associated with better functional status, with 100 representing no symptoms or evidence of disease, and 0 representing death.
      • Values Differ
      .experimentalfalse
      • Removed the item 'false'
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
            .kindresource
              .nameUSCoreLaboratoryResultObservationProfileKarnofskyPerformanceStatus
              • Values Differ
              .publisherHL7 International - US Realm Steering CommitteeHL7 International Clinical Interoperability Council
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Laboratory Result Observation ProfileKarnofsky Performance Status
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-labhttp://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status
                    • Values Differ
                    .version3.2.01.16.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation II
                    • Elements differ in definition: "This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements." "Measurements and simple assertions made about a patient, device or other subject."
                    ... id ΣΣ
                      ... meta ΣΣ
                        ... implicitRules ?!Σ?!Σ
                          ... language
                            ... text
                              ... contained
                                ... extension ExtensionExtension
                                  ... modifierExtension ?!?!
                                    ... identifier ΣΣ
                                      ... basedOn ΣΣ
                                      • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan], CanonicalType[http://hl7.org/fhir/StructureDefinition/DeviceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/NutritionOrder], CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan]])
                                      ... partOf ΣΣ
                                      • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationAdministration], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationDispense], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationStatement], CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure], CanonicalType[http://hl7.org/fhir/StructureDefinition/Immunization], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure]])
                                      ... status ?!SΣ?!SΣ
                                        ... category S(Slice Definition)(Slice Definition)
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        ... code SΣSΣ
                                        • Elements differ in short: "Laboratory Test Name" "Type of observation (code / type)"
                                        • Elements differ in definition: "The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."
                                        • Elements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                        • Elements differ in binding.description: "LOINC codes" "Codes identifying names of simple observations."
                                        ... subject SΣSΣ
                                          ... focus ΣΣ
                                            ... encounter ΣΣ
                                              ... effective[x] SΣISΣ
                                              • Elements differ in definition: "For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                              ... issued ΣΣ
                                                ... performer ΣΣ
                                                  ... value[x] SΣISΣI
                                                  • Elements differ in short: "Result Value" "Actual result"
                                                  • Elements differ in definition: "The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification." "The information determined as a result of making the observation, if the information has a simple value."
                                                  ... dataAbsentReason SII
                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                  ... interpretation S
                                                  • Elements differ in definition for mustSupport: "false" "true"
                                                  • Unable to resolve right value set http://loinc.org/vs/LL4986-7 at Observation.interpretation
                                                  ... note
                                                    ... bodySite
                                                    • Elements differ in short: "Observed body part" "Not used in this profile"
                                                    • Elements differ in definition: "Indicates the site on the subject's body where the observation was made (i.e. the target site)." "Not used in this profile"
                                                    ... method
                                                      ... specimen
                                                      • Elements differ in short: "Specimen used for this observation" "Not used in this profile"
                                                      • Elements differ in definition: "The specimen that was used when this observation was made." "Not used in this profile"
                                                      ... device
                                                      • Elements differ in short: "(Measurement) Device" "Not used in this profile"
                                                      • Elements differ in definition: "The device used to generate the observation data." "Not used in this profile"
                                                      ... referenceRange II
                                                        .... id
                                                          .... extension ExtensionExtension
                                                            .... modifierExtension ?!Σ?!Σ
                                                              .... low II
                                                                .... high II
                                                                  .... type
                                                                    .... appliesTo
                                                                      .... age
                                                                        .... text
                                                                          ... hasMember ΣΣ
                                                                          • Elements differ in short: "Related resource that belongs to the Observation group" "Not used in this profile"
                                                                          • Elements differ in definition: "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group." "Not used in this profile"
                                                                          ... derivedFrom ΣΣ
                                                                            ... component ΣΣ
                                                                            • Elements differ in short: "Component results" "Not used in this profile"
                                                                            • Elements differ in definition: "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations." "Not used in this profile"
                                                                            .... id
                                                                              .... extension ExtensionExtension
                                                                                .... modifierExtension ?!Σ?!Σ
                                                                                  .... code ΣΣ
                                                                                    .... value[x] ΣΣ
                                                                                      .... dataAbsentReason II
                                                                                        .... interpretation
                                                                                          .... referenceRange

                                                                                            doco Documentation for this format