Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate vs http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-disease-status

Left:US Core Heart Rate Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate)
Right:Cancer Disease Status (http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-disease-status)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-disease-status'
ErrorStructureDefinition.versionValues for version differ: '3.2.0' vs '1.16.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreHeartRateProfile' vs 'CancerDiseaseStatus'
InformationStructureDefinition.titleValues for title differ: 'US Core Heart Rate Profile' vs 'Cancer Disease Status'
InformationStructureDefinition.dateValues for date differ: '2020-11-17' vs '2021-04-15T12:44:45+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International Clinical Interoperability Council'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Heart Rate Profile' 'Measurements and simple assertions'
WarningObservationElements differ in definition: 'Defines constraints on Observation to represent heart rate observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.' 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservation.extensionElements differ in short: 'Additional content defined by implementations' 'Extension'
WarningObservation.extensionElements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' 'An Extension'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Heart Rate' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' 'Codes identifying names of simple observations.'
ErrorObservation.focusElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.specimenElements differ in short: 'Specimen used for this observation' 'Not used in this profile'
WarningObservation.specimenElements differ in definition: 'The specimen that was used when this observation was made.' 'Not used in this profile'
WarningObservation.deviceElements differ in short: '(Measurement) Device' 'Not used in this profile'
WarningObservation.deviceElements differ in definition: 'The device used to generate the observation data.' 'Not used in this profile'
WarningObservation.referenceRangeElements differ in short: 'Provides guide for interpretation' 'Not used in this profile'
WarningObservation.referenceRangeElements differ in definition: 'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.' 'Not used in this profile'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Not used in this profile'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'Not used in this profile'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Component observations' 'Not used in this profile'
WarningObservation.componentElements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' 'Not used in this profile'
ErrorObservation.componentElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2020-11-172021-04-15T12:44:45+00:00
    • Values Differ
    .descriptionDefines constraints on Observation to represent heart rate observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.A clinician's qualitative judgment on the current trend of the cancer, e.g., whether it is stable, worsening (progressing), or improving (responding). The judgment may be based a single type or multiple kinds of evidence, such as imaging data, assessment of symptoms, tumor markers, laboratory data, etc.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCoreHeartRateProfileCancerDiseaseStatus
            • Values Differ
            .publisherHL7 International - US Realm Steering CommitteeHL7 International Clinical Interoperability Council
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Heart Rate ProfileCancer Disease Status
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-ratehttp://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-disease-status
                  • Values Differ
                  .version3.2.01.16.0
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation II
                  • Elements differ in short: "US Core Heart Rate Profile" "Measurements and simple assertions"
                  • Elements differ in definition: "Defines constraints on Observation to represent heart rate observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile." "Measurements and simple assertions made about a patient, device or other subject."
                  ... id ΣΣ
                    ... meta ΣΣ
                      ... implicitRules ?!Σ?!Σ
                        ... language
                          ... text
                            ... contained
                              ... extension ExtensionExtension
                              • Elements differ in short: "Additional content defined by implementations" "Extension"
                              • Elements differ in definition: "May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension." "An Extension"
                              ... modifierExtension ?!?!
                                ... identifier ΣΣ
                                  ... basedOn ΣΣ
                                    ... partOf ΣΣ
                                      ... status ?!SΣ?!SΣ
                                        ... category S(Slice Definition)
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        ... code SΣSΣ
                                        • Elements differ in short: "Heart Rate" "Type of observation (code / type)"
                                        • Elements differ in definition: "Coded Responses from C-CDA Vital Sign Results." "Describes what was observed. Sometimes this is called the observation "name"."
                                        • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                        • Elements differ in binding.description: "The vital sign codes from the base FHIR and US Core Vital Signs." "Codes identifying names of simple observations."
                                        ... subject SΣSΣ
                                          ... focus ΣSΣ
                                          • Elements differ in definition for mustSupport: "false" "true"
                                          ... encounter ΣΣ
                                            ... effective[x] SΣISΣ
                                            • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                            • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                            ... issued ΣΣ
                                              ... performer ΣΣ
                                                ... value[x] SΣI(Slice Definition)SΣI
                                                • Elements differ in short: "Vital Signs Value" "Actual result"
                                                • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type." "The information determined as a result of making the observation, if the information has a simple value."
                                                • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                ... dataAbsentReason SISI
                                                  ... interpretation
                                                    ... note
                                                      ... bodySite
                                                        ... method
                                                          ... specimen
                                                          • Elements differ in short: "Specimen used for this observation" "Not used in this profile"
                                                          • Elements differ in definition: "The specimen that was used when this observation was made." "Not used in this profile"
                                                          ... device
                                                          • Elements differ in short: "(Measurement) Device" "Not used in this profile"
                                                          • Elements differ in definition: "The device used to generate the observation data." "Not used in this profile"
                                                          ... referenceRange II
                                                          • Elements differ in short: "Provides guide for interpretation" "Not used in this profile"
                                                          • Elements differ in definition: "Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two `referenceRange` elements would be used." "Not used in this profile"
                                                          .... id
                                                            .... extension ExtensionExtension
                                                              .... modifierExtension ?!Σ?!Σ
                                                                .... low II
                                                                  .... high II
                                                                    .... type
                                                                      .... appliesTo
                                                                        .... age
                                                                          .... text
                                                                            ... hasMember ΣΣ
                                                                            • Elements differ in short: "Used when reporting vital signs panel components" "Not used in this profile"
                                                                            • Elements differ in definition: "Used when reporting vital signs panel components." "Not used in this profile"
                                                                            • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                            ... derivedFrom ΣΣ
                                                                              ... component SΣIΣ
                                                                              • Elements differ in short: "Component observations" "Not used in this profile"
                                                                              • Elements differ in definition: "Used when reporting component observation such as systolic and diastolic blood pressure." "Not used in this profile"
                                                                              • Elements differ in definition for mustSupport: "true" "false"
                                                                              .... id
                                                                                .... extension ExtensionExtension
                                                                                  .... modifierExtension ?!Σ?!Σ
                                                                                    .... code SΣΣ
                                                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                                                    • Elements differ in binding.description: "The vital sign codes from the base FHIR and US Core Vital Signs." "Codes identifying names of simple observations."
                                                                                    .... value[x] SΣIΣ
                                                                                    • Elements differ in short: "Vital Sign Component Value" "Actual component result"
                                                                                    • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                    • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                                                    .... dataAbsentReason SII
                                                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                                                    .... interpretation
                                                                                      .... referenceRange

                                                                                        doco Documentation for this format