Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-regional-nodes-category' |
Error | StructureDefinition.version | Values for version differ: '3.2.0' vs '1.16.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreBodyHeightProfile' vs 'TNMRegionalNodesCategory' |
Information | StructureDefinition.title | Values for title differ: 'US Core Body Height Profile' vs 'TNM Regional Nodes Category' |
Information | StructureDefinition.date | Values for date differ: '2020-11-17' vs '2021-04-15T12:44:45+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International Clinical Interoperability Council' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'US Core Body Height Profile'
'Measurements and simple assertions' |
Warning | Observation | Elements differ in definition:
'Defines constraints on Observation to represent body height observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Body Height'
'Type of observation (code / type)' |
Warning | Observation.code | Elements differ in definition:
'Coded Responses from C-CDA Vital Sign Results.'
'Describes what was observed. Sometimes this is called the observation 'name'.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Error | Observation.focus | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinically relevant time/time-period for observation' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs Value'
'Actual result' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.method | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.device | Elements differ in short:
'(Measurement) Device'
'Not used in this profile' |
Warning | Observation.device | Elements differ in definition:
'The device used to generate the observation data.'
'Not used in this profile' |
Warning | Observation.referenceRange | Elements differ in short:
'Provides guide for interpretation'
'Not used in this profile' |
Warning | Observation.referenceRange | Elements differ in definition:
'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.'
'Not used in this profile' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Not used in this profile' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'Not used in this profile' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Warning | Observation.component | Elements differ in short:
'Component observations'
'Not used in this profile' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting component observation such as systolic and diastolic blood pressure.'
'Not used in this profile' |
Error | Observation.component | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Component Value'
'Actual component result' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |