Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-blood-pressure' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-disease-status' |
Error | StructureDefinition.version | Values for version differ: '3.2.0' vs '1.16.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreBloodPressureProfile' vs 'CancerDiseaseStatus' |
Information | StructureDefinition.title | Values for title differ: 'US Core Blood Pressure Profile' vs 'Cancer Disease Status' |
Information | StructureDefinition.date | Values for date differ: '2020-11-17' vs '2021-04-15T12:44:45+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International Clinical Interoperability Council' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'US Core Blood Pressure Profile'
'Measurements and simple assertions' |
Warning | Observation | Elements differ in definition:
'Defines constraints on Observation to represent diastolic and systolic blood pressure observations with standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Warning | Observation.extension | Elements differ in short:
'Additional content defined by implementations'
'Extension' |
Warning | Observation.extension | Elements differ in definition:
'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.'
'An Extension' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Blood Pressure'
'Type of observation (code / type)' |
Warning | Observation.code | Elements differ in definition:
'Coded Responses from C-CDA Vital Sign Results.'
'Describes what was observed. Sometimes this is called the observation 'name'.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Warning | Observation.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Error | Observation.focus | Elements differ in definition for mustSupport:
'false'
'true' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinically relevant time/time-period for observation' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs Value'
'Actual result' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Warning | Observation.specimen | Elements differ in short:
'Specimen used for this observation'
'Not used in this profile' |
Warning | Observation.specimen | Elements differ in definition:
'The specimen that was used when this observation was made.'
'Not used in this profile' |
Warning | Observation.device | Elements differ in short:
'(Measurement) Device'
'Not used in this profile' |
Warning | Observation.device | Elements differ in definition:
'The device used to generate the observation data.'
'Not used in this profile' |
Warning | Observation.referenceRange | Elements differ in short:
'Provides guide for interpretation'
'Not used in this profile' |
Warning | Observation.referenceRange | Elements differ in definition:
'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.'
'Not used in this profile' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Not used in this profile' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'Not used in this profile' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Warning | Observation.component | Elements differ in short:
'Component observations'
'Not used in this profile' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting component observation such as systolic and diastolic blood pressure.'
'Not used in this profile' |
Error | Observation.component | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Component Value'
'Actual component result' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |