Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:Dental Findings (http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings)

Messages

StructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings'Information
StructureDefinition.versionValues for version differ: '3.1.0' vs '0.1.0'Information
StructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'DentalFindings'Information
StructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'Dental Findings'Information
StructureDefinition.dateValues for date differ: '2019-08-20T00:00:00+10:00' vs '2020-08-10T19:19:49+00:00'Information
StructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'Payer/Provider Information Exchange Work Group'Information
StructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/oxygensat' vs 'http://hl7.org/fhir/StructureDefinition/Observation'Error
ObservationElements differ in short: "FHIR Oxygen Saturation Profile" "Measurements and simple assertions"Warning
ObservationElements differ in definition: "This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure." "Measurements and simple assertions made about a patient, device or other subject."Warning
Observation.statusElements differ in definition for mustSupport: "true" "false"Error
Observation.categoryElements differ in definition for mustSupport: "true" "false"Error
Observation.codeElements differ in short: "Oxygen Saturation by Pulse Oximetry" "Type of observation (code / type)"Warning
Observation.codeElements differ in definition: "Oxygen Saturation." "Describes what was observed. Sometimes this is called the observation "name"."Warning
Observation.codeElements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."Warning
Observation.codeElements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."Warning
Observation.codeElements differ in definition for mustSupport: "true" "false"Error
Observation.code.codingElements differ in definition for mustSupport: "true" "false"Error
Observation.subjectElements differ in definition for mustSupport: "true" "false"Error
Observation.effective[x]Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"Warning
Observation.effective[x]Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."Warning
Observation.effective[x]Elements differ in definition for mustSupport: "true" "false"Error
Observation.value[x]Elements differ in short: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Actual result"Warning
Observation.value[x]Elements differ in definition: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."Warning
Observation.value[x]Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."Warning
Observation.value[x]Elements differ in definition for mustSupport: "true" "false"Error
Observation.dataAbsentReasonElements differ in definition for mustSupport: "true" "false"Error
Observation.bodySiteExample/preferred bindings differ at Observation.bodySite using binding from DentalFindingsInformation
Observation.hasMemberElements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"Warning
Observation.hasMemberElements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."Warning
Observation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])Error
Observation.componentElements differ in short: "Used when reporting systolic and diastolic blood pressure." "Component results"Warning
Observation.componentElements differ in definition: "Used when reporting systolic and diastolic blood pressure." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations."Warning
Observation.componentElements differ in definition for mustSupport: "true" "false"Error
Observation.component.codeElements differ in definition for mustSupport: "true" "false"Error
Observation.component.codeElements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."Warning
Observation.component.value[x]Elements differ in short: "Vital Sign Value recorded with UCUM" "Actual component result"Warning
Observation.component.value[x]Elements differ in definition: "Vital Sign Value recorded with UCUM." "The information determined as a result of making the observation, if the information has a simple value."Warning
Observation.component.value[x]Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."Warning
Observation.component.value[x]Elements differ in definition for mustSupport: "true" "false"Error
Observation.component.dataAbsentReasonElements differ in definition for mustSupport: "true" "false"Error

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/oxygensathttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyright
      .date2019-08-20T00:00:00+10:002020-08-10T19:19:49+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for use in querying and retrieving inspired O2 by pulse oximetry observations.This profile is used to convey oral findings including findings of an Odontogram, Peridontal (overall assessment and tooth-specific observations), Intra and Extra Oral Soft Tissue, TMJ, TMD, and Occlusion. Note - findings in this profile often support associated diagnoses (FHIR Conditions).
      • Values Differ
      .experimentalfalse
      • Removed this item
      .fhirVersion4.0.1
        .kindresource
          .nameUSCorePulseOximetryProfileDentalFindings
          • Values Differ
          .publisherHL7 US Realm Steering CommitteePayer/Provider Information Exchange Work Group
          • Values Differ
          .purpose
            .statusactive
              .titleUS Core Pulse Oximetry ProfileDental Findings
              • Values Differ
              .typeObservation
                .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings
                • Values Differ
                .version3.1.00.1.0
                • Values Differ

                Structure

                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                .. Observation II
                • Elements differ in short: "FHIR Oxygen Saturation Profile" "Measurements and simple assertions"
                • Elements differ in definition: "This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile. INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure." "Measurements and simple assertions made about a patient, device or other subject."
                ... id ΣΣ
                  ... meta ΣIΣI
                    ... implicitRules ?!ΣI?!ΣI
                      ... language II
                        ... text II
                          ... contained
                            ... extension IExtensionIExtension
                              ... modifierExtension ?!I?!I
                                ... identifier ΣIΣI
                                  ... basedOn ΣIΣI
                                    ... partOf ΣIΣI
                                      ... status ?!SΣI?!ΣI
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... category SI(Slice Definition)I
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... code SΣIΣI
                                      • Elements differ in short: "Oxygen Saturation by Pulse Oximetry" "Type of observation (code / type)"
                                      • Elements differ in definition: "Oxygen Saturation." "Describes what was observed. Sometimes this is called the observation "name"."
                                      • Elements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                      • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      .... id
                                        .... extension IExtensionIExtension
                                          .... coding SΣI(Slice Definition)ΣI
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          .... text ΣIΣI
                                            ... subject SΣIΣI
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... focus ΣIΣI
                                              ... encounter ΣIΣI
                                                ... effective[x] SΣIΣI
                                                • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                                • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                ... issued ΣIΣI
                                                  ... performer ΣIΣI
                                                    ... value[x] SΣI(Slice Definition)ΣI
                                                    • Elements differ in short: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Actual result"
                                                    • Elements differ in definition: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                    • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... dataAbsentReason SII
                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                    ... interpretation II
                                                      ... note II
                                                        ... bodySite II
                                                        • Example/preferred bindings differ at Observation.bodySite using binding from DentalFindings
                                                        ... method II
                                                          ... specimen II
                                                            ... device II
                                                              ... referenceRange II
                                                                .... id
                                                                  .... extension IExtensionIExtension
                                                                    .... modifierExtension ?!ΣI?!ΣI
                                                                      .... low II
                                                                        .... high II
                                                                          .... type II
                                                                            .... appliesTo II
                                                                              .... age II
                                                                                .... text II
                                                                                  ... hasMember ΣIΣI
                                                                                  • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                                  • Elements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."
                                                                                  • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                                  ... derivedFrom ΣIΣI
                                                                                    ... component SΣI(Slice Definition)ΣI
                                                                                    • Elements differ in short: "Used when reporting systolic and diastolic blood pressure." "Component results"
                                                                                    • Elements differ in definition: "Used when reporting systolic and diastolic blood pressure." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations."
                                                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                                                    .... id
                                                                                      .... extension IExtensionIExtension
                                                                                        .... modifierExtension ?!ΣI?!ΣI
                                                                                          .... code SΣIΣI
                                                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                                                          • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                                                                          .... value[x] SΣIΣI
                                                                                          • Elements differ in short: "Vital Sign Value recorded with UCUM" "Actual component result"
                                                                                          • Elements differ in definition: "Vital Sign Value recorded with UCUM." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                          • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                                                          .... dataAbsentReason SII
                                                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                                                          .... interpretation II
                                                                                            .... referenceRange II

                                                                                              doco Documentation for this format