Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab vs http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings

Left:US Core Laboratory Result Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab)
Right:Dental Findings (http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings)

Messages

StructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings'Information
StructureDefinition.versionValues for version differ: '3.1.0' vs '0.1.0'Information
StructureDefinition.nameValues for name differ: 'USCoreLaboratoryResultObservationProfile' vs 'DentalFindings'Information
StructureDefinition.titleValues for title differ: 'US Core Laboratory Result Observation Profile' vs 'Dental Findings'Information
StructureDefinition.dateValues for date differ: '2019-08-19T00:00:00+10:00' vs '2020-08-10T19:19:49+00:00'Information
StructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'Payer/Provider Information Exchange Work Group'Information
ObservationElements differ in definition: "This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements." "Measurements and simple assertions made about a patient, device or other subject."Warning
Observation.statusElements differ in definition for mustSupport: "true" "false"Error
Observation.categoryElements differ in definition for mustSupport: "true" "false"Error
Observation.codeElements differ in short: "Laboratory Test Name" "Type of observation (code / type)"Warning
Observation.codeElements differ in definition: "The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."Warning
Observation.codeElements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."Warning
Observation.codeElements differ in definition for mustSupport: "true" "false"Error
Observation.subjectElements differ in definition for mustSupport: "true" "false"Error
Observation.effective[x]Elements differ in definition: "For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."Warning
Observation.effective[x]Elements differ in definition for mustSupport: "true" "false"Error
Observation.value[x]Elements differ in short: "Result Value" "Actual result"Warning
Observation.value[x]Elements differ in definition: "The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification." "The information determined as a result of making the observation, if the information has a simple value."Warning
Observation.value[x]Elements differ in definition for mustSupport: "true" "false"Error
Observation.dataAbsentReasonElements differ in definition for mustSupport: "true" "false"Error
Observation.bodySiteExample/preferred bindings differ at Observation.bodySite using binding from DentalFindingsInformation

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observation
      .copyright
        .date2019-08-19T00:00:00+10:002020-08-10T19:19:49+00:00
        • Values Differ
        .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve laboratory test resultsThis profile is used to convey oral findings including findings of an Odontogram, Peridontal (overall assessment and tooth-specific observations), Intra and Extra Oral Soft Tissue, TMJ, TMD, and Occlusion. Note - findings in this profile often support associated diagnoses (FHIR Conditions).
        • Values Differ
        .experimentalfalse
        • Removed this item
        .fhirVersion4.0.1
          .kindresource
            .nameUSCoreLaboratoryResultObservationProfileDentalFindings
            • Values Differ
            .publisherHL7 US Realm Steering CommitteePayer/Provider Information Exchange Work Group
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Laboratory Result Observation ProfileDental Findings
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-labhttp://hl7.org/fhir/us/dental-data-exchange/StructureDefinition/dental-findings
                  • Values Differ
                  .version3.1.00.1.0
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation II
                  • Elements differ in definition: "This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements." "Measurements and simple assertions made about a patient, device or other subject."
                  ... id ΣΣ
                    ... meta ΣIΣI
                      ... implicitRules ?!ΣI?!ΣI
                        ... language II
                          ... text II
                            ... contained
                              ... extension IExtensionIExtension
                                ... modifierExtension ?!I?!I
                                  ... identifier ΣIΣI
                                    ... basedOn ΣIΣI
                                      ... partOf ΣIΣI
                                        ... status ?!SΣI?!ΣI
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        ... category SI(Slice Definition)I
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        ... code SΣIΣI
                                        • Elements differ in short: "Laboratory Test Name" "Type of observation (code / type)"
                                        • Elements differ in definition: "The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."
                                        • Elements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        ... subject SΣIΣI
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        ... focus ΣIΣI
                                          ... encounter ΣIΣI
                                            ... effective[x] SΣIΣI
                                            • Elements differ in definition: "For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... issued ΣIΣI
                                              ... performer ΣIΣI
                                                ... value[x] SΣIΣI
                                                • Elements differ in short: "Result Value" "Actual result"
                                                • Elements differ in definition: "The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT]. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification." "The information determined as a result of making the observation, if the information has a simple value."
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                ... dataAbsentReason SII
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                ... interpretation II
                                                  ... note II
                                                    ... bodySite II
                                                    • Example/preferred bindings differ at Observation.bodySite using binding from DentalFindings
                                                    ... method II
                                                      ... specimen II
                                                        ... device II
                                                          ... referenceRange II
                                                            .... id
                                                              .... extension IExtensionIExtension
                                                                .... modifierExtension ?!ΣI?!ΣI
                                                                  .... low II
                                                                    .... high II
                                                                      .... type II
                                                                        .... appliesTo II
                                                                          .... age II
                                                                            .... text II
                                                                              ... hasMember ΣIΣI
                                                                                ... derivedFrom ΣIΣI
                                                                                  ... component ΣIΣI
                                                                                    .... id
                                                                                      .... extension IExtensionIExtension
                                                                                        .... modifierExtension ?!ΣI?!ΣI
                                                                                          .... code ΣIΣI
                                                                                            .... value[x] ΣIΣI
                                                                                              .... dataAbsentReason II
                                                                                                .... interpretation II
                                                                                                  .... referenceRange II

                                                                                                    doco Documentation for this format