US Core Implementation Guide
8.0.0-ballot - STU8 Ballot United States of America flag

This page is part of the US Core (v8.0.0-ballot: STU8 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 7.0.0. For a full list of available versions, see the Directory of published versions

: At Home In Vitro Test Example - XML Representation

Page standards status: Informative

Raw xml | Download


<Observation xmlns="http://hl7.org/fhir">
  <id value="at-home-in-vitro-test"/>
  <meta>
    <lastUpdated value="2021-01-28T16:06:21-05:00"/>
    <profile
             value="http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab|8.0.0-ballot"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Observation at-home-in-vitro-test</b></p><a name="at-home-in-vitro-test"> </a><a name="hcat-home-in-vitro-test"> </a><a name="at-home-in-vitro-test-en-US"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Last updated: 2021-01-28 16:06:21-0500</p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-us-core-observation-lab.html">US Core Laboratory Result Observation Profileversion: null8.0.0-ballot)</a></p></div><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category laboratory}">Laboratory</span></p><p><b>code</b>: <span title="Codes:{http://loinc.org 95209-3}">SARS-CoV+SARS-CoV-2 (COVID-19) Ag [Presence] in Respiratory system specimen by Rapid immunoassay</span></p><p><b>subject</b>: <a href="Patient-example.html">Amy V. Baxter  Female, DoB: 1987-02-20 ( Medical Record Number: 1032702 (use: usual, ))</a></p><p><b>encounter</b>: <a href="Encounter-example-1.html">Office Visit</a></p><p><b>effective</b>: 2021-01-28 16:06:21-0500</p><p><b>performer</b>: <a href="Patient-example.html">Amy V. Baxter  Female, DoB: 1987-02-20 ( Medical Record Number: 1032702 (use: usual, ))</a></p><p><b>value</b>: <span title="Codes:{http://snomed.info/sct 260373001}">Detected</span></p><p><b>device</b>: Acme COVID-19 Home Test_Acme Limited</p></div>
  </text>
  <status value="final"/>
  <category>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/observation-category"/>
      <code value="laboratory"/>
      <display value="Laboratory"/>
    </coding>
    <text value="Laboratory"/>
  </category>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="95209-3"/>
      <display
               value="SARS-CoV+SARS-CoV-2 (COVID-19) Ag [Presence] in Respiratory system specimen by Rapid immunoassay"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/example"/>
  </subject>
  <encounter>🔗 
    <reference value="Encounter/example-1"/>
    <display value="Office Visit"/>
  </encounter>
  <effectiveDateTime value="2021-01-28T16:06:21-05:00"/>
  <performer>🔗 
    <reference value="Patient/example"/>
  </performer>
  <valueCodeableConcept>
    <coding>
      <system value="http://snomed.info/sct"/>
      <version value="http://snomed.info/sct/731000124108"/>
      <code value="260373001"/>
      <display value="Detected"/>
    </coding>
  </valueCodeableConcept>
  <device>
    <display value="Acme COVID-19 Home Test_Acme Limited"/>
  </device>
</Observation>