This page is part of the Breast Cancer Data Logical Models and FHIR Profiles (v0.1.0: STU 1 Draft) based on FHIR R3. . For a full list of available versions, see the Directory of published versions
<StructureDefinition xmlns="http://hl7.org/fhir"> <id value="shr-core-SimpleQuantity-model"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p><b>BC SimpleQuantity Logical Model</b></p> <p>A quantity where the comparator is not used, as defined in FHIR. This class is not defined in CIMI V0.0.4 reference model. It could potentially be an archetype of Quantity. Complex data types that appear frequently in FHIR have not been profiled, even if CIMI defines them differently. This choice means that the breast cancer profiles use the native FHIR datatype, rather than having to substitute a CIMI profile everywhere the native type is used.</p> </div> </text> <url value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/shr-core-SimpleQuantity-model"/> <identifier> <system value="http://hl7.org/fhir/us/breastcancer"/> <value value="shr.core.SimpleQuantity"/> </identifier> <version value="0.1.0"/> <name value="SimpleQuantityModel"/> <title value="BC SimpleQuantity Logical Model"/> <status value="draft"/> <date value="2018-04-01T00:00:00+11:00"/> <publisher value="The HL7 Cancer Interoperability Group sponsored by Clinical Interoperability Council Work Group (CIC)"/> <contact> <telecom> <system value="url"/> <value value="http://standardhealthrecord.org"/> </telecom> </contact> <description value="A quantity where the comparator is not used, as defined in FHIR. This class is not defined in CIMI V0.0.4 reference model. It could potentially be an archetype of Quantity. Complex data types that appear frequently in FHIR have not been profiled, even if CIMI defines them differently. This choice means that the breast cancer profiles use the native FHIR datatype, rather than having to substitute a CIMI profile everywhere the native type is used."/> <kind value="logical"/> <abstract value="false"/> <type value="shr-core-SimpleQuantity-model"/> <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Element"/> <derivation value="specialization"/> <snapshot> <element id="shr-core-SimpleQuantity-model"> <path value="shr-core-SimpleQuantity-model"/> <definition value="A quantity where the comparator is not used, as defined in FHIR. This class is not defined in CIMI V0.0.4 reference model. It could potentially be an archetype of Quantity. Complex data types that appear frequently in FHIR have not been profiled, even if CIMI defines them differently. This choice means that the breast cancer profiles use the native FHIR datatype, rather than having to substitute a CIMI profile everywhere the native type is used."/> <min value="0"/> <max value="*"/> <base> <path value="shr-core-SimpleQuantity-model"/> <min value="0"/> <max value="*"/> </base> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="shr-core-SimpleQuantity-model.value"> <path value="shr-core-SimpleQuantity-model.value"/> <short value="Decimal representing a quantity where the comparator is not used, as defined in FHIR."/> <definition value="Decimal representing a quantity where the comparator is not used, as defined in FHIR. This class is not defined in CIMI V0.0.4 reference model. It could potentially be an archetype of Quantity. Complex data types that appear frequently in FHIR have not been profiled, even if CIMI defines them differently. This choice means that the breast cancer profiles use the native FHIR datatype, rather than having to substitute a CIMI profile everywhere the native type is used."/> <alias value="decimal"/> <min value="0"/> <max value="1"/> <base> <path value="shr-core-SimpleQuantity-model.value"/> <min value="0"/> <max value="1"/> </base> <type> <code value="decimal"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="shr-core-SimpleQuantity-model.comparator"> <path value="shr-core-SimpleQuantity-model.comparator"/> <short value="Comparator"/> <definition value="Comparator"/> <min value="0"/> <max value="0"/> <base> <path value="shr-core-SimpleQuantity-model.comparator"/> <min value="0"/> <max value="0"/> </base> <type> <code value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/shr-core-Comparator-model"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="shr-core-SimpleQuantity-model.units"> <path value="shr-core-SimpleQuantity-model.units"/> <short value="Code for the unit of measure of the quantity."/> <definition value="Code for the unit of measure of the quantity."/> <min value="0"/> <max value="1"/> <base> <path value="shr-core-SimpleQuantity-model.units"/> <min value="0"/> <max value="1"/> </base> <type> <code value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/shr-core-Units-model"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> </snapshot> <differential> <element id="shr-core-SimpleQuantity-model"> <path value="shr-core-SimpleQuantity-model"/> <definition value="A quantity where the comparator is not used, as defined in FHIR. This class is not defined in CIMI V0.0.4 reference model. It could potentially be an archetype of Quantity. Complex data types that appear frequently in FHIR have not been profiled, even if CIMI defines them differently. This choice means that the breast cancer profiles use the native FHIR datatype, rather than having to substitute a CIMI profile everywhere the native type is used."/> <min value="0"/> <max value="*"/> <base> <path value="shr-core-SimpleQuantity-model"/> <min value="0"/> <max value="*"/> </base> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="shr-core-SimpleQuantity-model.value"> <path value="shr-core-SimpleQuantity-model.value"/> <short value="Decimal representing a quantity where the comparator is not used, as defined in FHIR."/> <definition value="Decimal representing a quantity where the comparator is not used, as defined in FHIR. This class is not defined in CIMI V0.0.4 reference model. It could potentially be an archetype of Quantity. Complex data types that appear frequently in FHIR have not been profiled, even if CIMI defines them differently. This choice means that the breast cancer profiles use the native FHIR datatype, rather than having to substitute a CIMI profile everywhere the native type is used."/> <alias value="decimal"/> <min value="0"/> <max value="1"/> <base> <path value="shr-core-SimpleQuantity-model.value"/> <min value="0"/> <max value="1"/> </base> <type> <code value="decimal"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="shr-core-SimpleQuantity-model.comparator"> <path value="shr-core-SimpleQuantity-model.comparator"/> <short value="Comparator"/> <definition value="Comparator"/> <min value="0"/> <max value="0"/> <base> <path value="shr-core-SimpleQuantity-model.comparator"/> <min value="0"/> <max value="0"/> </base> <type> <code value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/shr-core-Comparator-model"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="shr-core-SimpleQuantity-model.units"> <path value="shr-core-SimpleQuantity-model.units"/> <short value="Code for the unit of measure of the quantity."/> <definition value="Code for the unit of measure of the quantity."/> <min value="0"/> <max value="1"/> <base> <path value="shr-core-SimpleQuantity-model.units"/> <min value="0"/> <max value="1"/> </base> <type> <code value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/shr-core-Units-model"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> </differential> </StructureDefinition>