This page is part of the Breast Cancer Data Logical Models and FHIR Profiles (v0.1.0: STU 1 Draft) based on FHIR R3. . For a full list of available versions, see the Directory of published versions
<StructureDefinition xmlns="http://hl7.org/fhir"> <id value="cimi-SourceSpecimen-model"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p><b>BC SourceSpecimen Logical Model</b></p> <p>Identifier for the source specimen from which this specimen was derived. CIMI Alignment: In CIMI V0.0.4, this attribute is called parentSpecimenIdentifier (datatype Identifier). The corresponding element in FHIR (Specimen.parent) is type ref(Specimen). It is impossible to map Idenfier to Specimen, so the datatype of this element has been changed to make the mapping feasible.</p> </div> </text> <url value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/cimi-SourceSpecimen-model"/> <identifier> <system value="http://hl7.org/fhir/us/breastcancer"/> <value value="cimi.SourceSpecimen"/> </identifier> <version value="0.1.0"/> <name value="SourceSpecimenModel"/> <title value="BC SourceSpecimen Logical Model"/> <status value="draft"/> <date value="2018-04-01T00:00:00+11:00"/> <publisher value="The HL7 Cancer Interoperability Group sponsored by Clinical Interoperability Council Work Group (CIC)"/> <contact> <telecom> <system value="url"/> <value value="http://standardhealthrecord.org"/> </telecom> </contact> <description value="Identifier for the source specimen from which this specimen was derived. CIMI Alignment: In CIMI V0.0.4, this attribute is called parentSpecimenIdentifier (datatype Identifier). The corresponding element in FHIR (Specimen.parent) is type ref(Specimen). It is impossible to map Idenfier to Specimen, so the datatype of this element has been changed to make the mapping feasible."/> <kind value="logical"/> <abstract value="false"/> <type value="cimi-SourceSpecimen-model"/> <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Element"/> <derivation value="specialization"/> <snapshot> <element id="cimi-SourceSpecimen-model"> <path value="cimi-SourceSpecimen-model"/> <definition value="Identifier for the source specimen from which this specimen was derived. CIMI Alignment: In CIMI V0.0.4, this attribute is called parentSpecimenIdentifier (datatype Identifier). The corresponding element in FHIR (Specimen.parent) is type ref(Specimen). It is impossible to map Idenfier to Specimen, so the datatype of this element has been changed to make the mapping feasible."/> <min value="0"/> <max value="*"/> <base> <path value="cimi-SourceSpecimen-model"/> <min value="0"/> <max value="*"/> </base> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="cimi-SourceSpecimen-model.value"> <path value="cimi-SourceSpecimen-model.value"/> <short value="Specimen representing identifier for the source specimen from which this specimen was derived."/> <definition value="Specimen representing identifier for the source specimen from which this specimen was derived. CIMI Alignment: In CIMI V0.0.4, this attribute is called parentSpecimenIdentifier (datatype Identifier). The corresponding element in FHIR (Specimen.parent) is type ref(Specimen). It is impossible to map Idenfier to Specimen, so the datatype of this element has been changed to make the mapping feasible."/> <alias value="specimen"/> <min value="1"/> <max value="1"/> <base> <path value="cimi-SourceSpecimen-model.value"/> <min value="1"/> <max value="1"/> </base> <type> <code value="Reference"/> <targetProfile value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/cimi-Specimen-model"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> </snapshot> <differential> <element id="cimi-SourceSpecimen-model"> <path value="cimi-SourceSpecimen-model"/> <definition value="Identifier for the source specimen from which this specimen was derived. CIMI Alignment: In CIMI V0.0.4, this attribute is called parentSpecimenIdentifier (datatype Identifier). The corresponding element in FHIR (Specimen.parent) is type ref(Specimen). It is impossible to map Idenfier to Specimen, so the datatype of this element has been changed to make the mapping feasible."/> <min value="0"/> <max value="*"/> <base> <path value="cimi-SourceSpecimen-model"/> <min value="0"/> <max value="*"/> </base> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> <element id="cimi-SourceSpecimen-model.value"> <path value="cimi-SourceSpecimen-model.value"/> <short value="Specimen representing identifier for the source specimen from which this specimen was derived."/> <definition value="Specimen representing identifier for the source specimen from which this specimen was derived. CIMI Alignment: In CIMI V0.0.4, this attribute is called parentSpecimenIdentifier (datatype Identifier). The corresponding element in FHIR (Specimen.parent) is type ref(Specimen). It is impossible to map Idenfier to Specimen, so the datatype of this element has been changed to make the mapping feasible."/> <alias value="specimen"/> <min value="1"/> <max value="1"/> <base> <path value="cimi-SourceSpecimen-model.value"/> <min value="1"/> <max value="1"/> </base> <type> <code value="Reference"/> <targetProfile value="http://hl7.org/fhir/us/breastcancer/StructureDefinition/cimi-Specimen-model"/> </type> <mustSupport value="false"/> <isModifier value="false"/> <isSummary value="false"/> </element> </differential> </StructureDefinition>