This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Not linked to any defined compartments |
IV Chemotherapy Example - Manufactured Product - Adcetris
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Medication/med0306> a fhir:Medication; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "med0306"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: med0306</p><p><b>contained</b>: </p><p><b>code</b>: Adcetris <span>(Details : {http://hl7.org/fhir/sid/ndc code '51144-050-01' = '51144-050-01', given as 'Adcetris'})</span></p><p><b>isBrand</b>: true</p><p><b>manufacturer</b>: id: org3; name: Seattle Genetics Inc</p><p><b>form</b>: Lyophilized powder for injectable solution (qualifier value) <span>(Details : {SNOMED CT code '421637006' = 'Lyophilised powder for injectable solution', given as 'Lyophilized powder for injectable solution (qualifier value) '})</span></p><blockquote><p><b>package</b></p><h3>Batches</h3><table><tr><td>-</td><td><b>LotNumber</b></td><td><b>ExpirationDate</b></td></tr><tr><td>*</td><td>12345</td><td>31/10/2019</td></tr></table></blockquote></div>" ]; fhir:DomainResource.contained [ a fhir:Organization; fhir:index 0; fhir:Resource.id [ fhir:value "org3" ]; fhir:Organization.name [ fhir:value "Seattle Genetics Inc" ] ]; fhir:Medication.code [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ]; fhir:Coding.code [ fhir:value "51144-050-01" ]; fhir:Coding.display [ fhir:value "Adcetris" ] ] ]; fhir:Medication.isBrand [ fhir:value "true"^^xsd:boolean]; fhir:Medication.manufacturer [ fhir:Reference.reference [ fhir:value "#org3" ] ]; fhir:Medication.form [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:421637006; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "421637006" ]; fhir:Coding.display [ fhir:value "Lyophilized powder for injectable solution (qualifier value) " ] ] ]; fhir:Medication.package [ fhir:Medication.package.batch [ fhir:index 0; fhir:Medication.package.batch.lotNumber [ fhir:value "12345" ]; fhir:Medication.package.batch.expirationDate [ fhir:value "2019-10-31"^^xsd:date ] ] ] . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Medication/med0306.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://hl7.org/fhir/STU3/Medication/med0306.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.