Release 4B

This page is part of the FHIR Specification (v4.3.0: R4B - STU). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Supplydelivery-example.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient, Practitioner

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Simple delivery for resupply (id = "simpledelivery")

<?xml version="1.0" encoding="UTF-8"?>

<SupplyDelivery xmlns="http://hl7.org/fhir">
  <id value="simpledelivery"/> 
  <!--   
business identifier - in this case the same as the request id
   -->
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px
       solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource &quot;simpledelivery&quot; </p> </div> <p> <b> identifier</b> : id: Order10284</p> <p> <b> basedOn</b> : <a href="supplyrequest-simpleorder.html">SupplyRequest/simpleorder</a> </p> <p> <b> partOf</b> : <span> : Central Supply Restock</span> </p> <p> <b> status</b> : completed</p> <p> <b> type</b> : Blood collect tubes blue cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-supplydelivery-type.html">Supply Item Type</a> #device)</span> </p> <h3> SuppliedItems</h3> <table class="grid"><tr> <td> -</td> <td> <b> Quantity</b> </td> <td> <b> Item[x]</b> </td> </tr> <tr> <td> *</td> <td> 10</td> <td> Blood collect tubes blue cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ([not stated]#BlueTubes)</span> </td> </tr> </table> <p> <b> occurrence</b> : 2016-12-31</p> <p> <b> supplier</b> : <span> : Vendor1</span> </p> <p> <b> destination</b> : <span> : Location 1</span> </p> </div> </text> <identifier> 
    <value value="Order10284"/> 
  </identifier> 
  <basedOn> 
    <reference value="SupplyRequest/simpleorder"/> 
  </basedOn> 
  <partOf> 
    <display value="Central Supply Restock"/> 
  </partOf> 
  <status value="completed"/> 
  <type> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/supply-item-type"/> 
      <code value="device"/> 
    </coding> 
    <text value="Blood collect tubes blue cap"/> 
  </type> 
  <suppliedItem> 
    <quantity> 
      <value value="10"/> 
    </quantity> 
    <itemCodeableConcept> 
      <coding> 
        <code value="BlueTubes"/> 
        <display value="Blood collect tubes blue cap"/> 
      </coding> 
    </itemCodeableConcept> 
  </suppliedItem> 
  <occurrenceDateTime value="2016-12-31"/> 
  <supplier> 
    <display value="Vendor1"/> 
  </supplier> 
  <destination> 
    <display value="Location 1"/> 
  </destination> 
</SupplyDelivery> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.