This page is part of the FHIR Specification (v4.3.0: R4B - STU). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Example of an order for an implant
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/ServiceRequest/example-implant> a fhir:ServiceRequest; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "example-implant"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource "example-implant" </p></div><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>code</b>: Implant Pacemaker <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#25267002 "Insertion of intracardiac pacemaker (procedure)")</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</p><p><b>authoredOn</b>: 2015-03-30</p><p><b>requester</b>: <a href=\"practitioner-3ad0687e-f477-468c-afd5-fcc2bf897809.html\">Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809: Dr. Beverly Crusher</a></p><p><b>performer</b>: <a href=\"practitioner-example.html\">Practitioner/example: Dr Cecil Surgeon</a> "Adam CAREFUL"</p><p><b>reasonCode</b>: Bradycardia <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p></div>" ]; fhir:ServiceRequest.status [ fhir:value "completed"]; fhir:ServiceRequest.intent [ fhir:value "order"]; fhir:ServiceRequest.code [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:25267002; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "25267002" ]; fhir:Coding.display [ fhir:value "Insertion of intracardiac pacemaker (procedure)" ] ]; fhir:CodeableConcept.text [ fhir:value "Implant Pacemaker" ] ]; fhir:ServiceRequest.subject [ fhir:link <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ]; fhir:ServiceRequest.authoredOn [ fhir:value "2015-03-30"^^xsd:date]; fhir:ServiceRequest.requester [ fhir:link <http://hl7.org/fhir/Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809>; fhir:Reference.reference [ fhir:value "Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809" ]; fhir:Reference.display [ fhir:value "Dr. Beverly Crusher" ] ]; fhir:ServiceRequest.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Practitioner/example>; fhir:Reference.reference [ fhir:value "Practitioner/example" ]; fhir:Reference.display [ fhir:value "Dr Cecil Surgeon" ] ]; fhir:ServiceRequest.reasonCode [ fhir:index 0; fhir:CodeableConcept.text [ fhir:value "Bradycardia" ] ] . <http://hl7.org/fhir/Patient/example> a fhir:Patient . <http://hl7.org/fhir/Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809> a fhir:Practitioner . <http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/ServiceRequest/example-implant.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/ServiceRequest/example-implant.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.