Release 4B

This page is part of the FHIR Specification (v4.3.0: R4B - STU). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationrequest0323.ttl

Pharmacy Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner

Raw Turtle (+ also see Turtle/RDF Format Specification)

Request for TPN Solution - completed

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/MedicationRequest/medrx0323> a fhir:MedicationRequest;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "medrx0323"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource &quot;medrx0323&quot; </p></div><p><b>identifier</b>: id: 12345689 (OFFICIAL)</p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>medication</b>: <a name=\"med0318\"> </a></p><blockquote><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource &quot;med0318&quot; </p></div><p><b>form</b>: Injection emulsion <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#385221006)</span></p><blockquote><p><b>ingredient</b></p><p><b>item</b>: Clinimix 4.25/10 sulfite-free (4.25% Amino Acid in 10% Dextrose) Injection, 1000ml <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-ndc.html\">National drug codes</a>#0338-1134-03)</span></p></blockquote><blockquote><p><b>ingredient</b></p><p><b>item</b>: TPN Electrolytes SODIUM CHLORIDE, CALCIUM CHLORIDE, POTASSIUM CHLORIDE, MAGNESIUM CHLORIDE, and SODIUM ACETATE ANHYDROUS | INJECTION, SOLUTION, CONCENTRATE | 321 mg/20mL, 331 mg/20mL, 1491 mg/20mL, 508 mg/20mL, 2420 mg/20mL <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-ndc.html\">National drug codes</a>#0409-5779-01)</span></p></blockquote><blockquote><p><b>ingredient</b></p><p><b>item</b>: Intralipid 20% IV Fat Emulsion <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-ndc.html\">National drug codes</a>#0338-0519-02)</span></p></blockquote><h3>Batches</h3><table class=\"grid\"><tr><td>-</td><td><b>LotNumber</b></td><td><b>ExpirationDate</b></td></tr><tr><td>*</td><td>123455</td><td>2016-07-09</td></tr></table></blockquote><p><b>subject</b>: <a href=\"patient-pat1.html\">Patient/pat1: Donald Duck</a> &quot;Duck DONALD&quot;</p><p><b>encounter</b>: <a href=\"encounter-f001.html\">Encounter/f001: encounter who leads to this prescription</a></p><p><b>authoredOn</b>: 2015-01-15</p><p><b>requester</b>: <a href=\"practitioner-f007.html\">Practitioner/f007: Patrick Pump</a> &quot;Simone HEPS&quot;</p></div>"
  ];
  fhir:DomainResource.contained [
     a fhir:Medication;
     fhir:index 0;
     fhir:Resource.id [ fhir:value "med0318" ];
     fhir:Medication.form [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:385221006;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "385221006" ];
         fhir:Coding.display [ fhir:value "Injection emulsion" ]
       ]
     ];
     fhir:Medication.ingredient [
       fhir:index 0;
       fhir:Medication.ingredient.itemCodeableConcept [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
           fhir:Coding.code [ fhir:value "0338-1134-03" ];
           fhir:Coding.display [ fhir:value "Clinimix 4.25/10 sulfite-free (4.25% Amino Acid in 10% Dextrose) Injection, 1000ml" ]
         ]
       ]
     ], [
       fhir:index 1;
       fhir:Medication.ingredient.itemCodeableConcept [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
           fhir:Coding.code [ fhir:value "0409-5779-01" ];
           fhir:Coding.display [ fhir:value "TPN Electrolytes SODIUM CHLORIDE, CALCIUM CHLORIDE, POTASSIUM CHLORIDE, MAGNESIUM CHLORIDE, and SODIUM ACETATE ANHYDROUS | INJECTION, SOLUTION, CONCENTRATE | 321 mg/20mL, 331 mg/20mL, 1491 mg/20mL, 508 mg/20mL, 2420 mg/20mL" ]
         ]
       ]
     ], [
       fhir:index 2;
       fhir:Medication.ingredient.itemCodeableConcept [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
           fhir:Coding.code [ fhir:value "0338-0519-02" ];
           fhir:Coding.display [ fhir:value "Intralipid 20% IV Fat Emulsion" ]
         ]
       ]
     ];
     fhir:Medication.batch [
       fhir:Medication.batch.lotNumber [ fhir:value "123455" ];
       fhir:Medication.batch.expirationDate [ fhir:value "2016-07-09"^^xsd:date ]
     ]
  ];
  fhir:MedicationRequest.identifier [
     fhir:index 0;
     fhir:Identifier.use [ fhir:value "official" ];
     fhir:Identifier.system [ fhir:value "http://www.bmc.nl/portal/prescriptions" ];
     fhir:Identifier.value [ fhir:value "12345689" ]
  ];
  fhir:MedicationRequest.status [ fhir:value "completed"];
  fhir:MedicationRequest.intent [ fhir:value "order"];
  fhir:MedicationRequest.medicationReference [
     fhir:Reference.reference [ fhir:value "#med0318" ]
  ];
  fhir:MedicationRequest.subject [
     fhir:link <http://hl7.org/fhir/Patient/pat1>;
     fhir:Reference.reference [ fhir:value "Patient/pat1" ];
     fhir:Reference.display [ fhir:value "Donald Duck" ]
  ];
  fhir:MedicationRequest.encounter [
     fhir:link <http://hl7.org/fhir/Encounter/f001>;
     fhir:Reference.reference [ fhir:value "Encounter/f001" ];
     fhir:Reference.display [ fhir:value "encounter who leads to this prescription" ]
  ];
  fhir:MedicationRequest.authoredOn [ fhir:value "2015-01-15"^^xsd:date];
  fhir:MedicationRequest.requester [
     fhir:link <http://hl7.org/fhir/Practitioner/f007>;
     fhir:Reference.reference [ fhir:value "Practitioner/f007" ];
     fhir:Reference.display [ fhir:value "Patrick Pump" ]
  ];
  fhir:MedicationRequest.dosageInstruction [
     fhir:index 0;
     fhir:Dosage.sequence [ fhir:value "1"^^xsd:integer ];
     fhir:Dosage.text [ fhir:value "1000mL infused at 50ml/hour for 4 hours - hung at 2200 hours" ];
     fhir:Dosage.timing [
       fhir:Timing.event [
         fhir:value "2015-01-15T22:00:00+11:00"^^xsd:dateTime;
         fhir:index 0
       ];
       fhir:Timing.repeat [
         fhir:Timing.repeat.frequency [ fhir:value "1"^^xsd:positiveInteger ];
         fhir:Timing.repeat.period [ fhir:value "24"^^xsd:decimal ];
         fhir:Timing.repeat.periodUnit [ fhir:value "h" ]
       ]
     ];
     fhir:Dosage.site [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:6073002;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "6073002" ];
         fhir:Coding.display [ fhir:value "Structure of ligament of left superior vena cava" ]
       ]
     ];
     fhir:Dosage.route [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:255560000;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "255560000" ];
         fhir:Coding.display [ fhir:value "Intravenous" ]
       ]
     ];
     fhir:Dosage.method [
       fhir:CodeableConcept.text [ fhir:value "PICC line" ]
     ];
     fhir:Dosage.doseAndRate [
       fhir:index 0;
       fhir:Dosage.doseAndRate.type [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/dose-rate-type" ];
           fhir:Coding.code [ fhir:value "ordered" ];
           fhir:Coding.display [ fhir:value "Ordered" ]
         ]
       ];
       fhir:Dosage.doseAndRate.doseQuantity [
         fhir:Quantity.value [ fhir:value "1000"^^xsd:decimal ];
         fhir:Quantity.unit [ fhir:value "mL" ];
         fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
         fhir:Quantity.code [ fhir:value "mL" ]
       ];
       fhir:Dosage.doseAndRate.rateRatio [
         fhir:Ratio.numerator [
           fhir:Quantity.value [ fhir:value "50"^^xsd:decimal ];
           fhir:Quantity.unit [ fhir:value "mL" ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "mL" ]
         ];
         fhir:Ratio.denominator [
           fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ];
           fhir:Quantity.unit [ fhir:value "h" ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "h" ]
         ]
       ]
     ]
  ] .

<http://hl7.org/fhir/Patient/pat1> a fhir:Patient .

<http://hl7.org/fhir/Encounter/f001> a fhir:Encounter .

<http://hl7.org/fhir/Practitioner/f007> a fhir:Practitioner .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/MedicationRequest/medrx0323.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/MedicationRequest/medrx0323.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.