This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Blood Pressure Measurement with an absent Diastolic measurement
{ "resourceType": "Observation", "id": "blood-pressure-dar", "meta": { "profile": [ "http://hl7.org/fhir/StructureDefinition/vitalsigns" ] }, "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: blood-pressure-dar</p><p><b>meta</b>: </p><p><b>identifier</b>: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span>(Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'vital-signs' = 'Vital Signs', given as 'Vital Signs'})</span></p><p><b>code</b>: Blood pressure systolic & diastolic <span>(Details : {LOINC code '85354-9' = 'Blood pressure panel with all children optional', given as 'Blood pressure panel with all children optional'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 17/09/2012</p><p><b>performer</b>: <a>Practitioner/example</a></p><p><b>interpretation</b>: Below low normal <span>(Details : {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation code 'L' = 'Low', given as 'low'})</span></p><p><b>bodySite</b>: Right arm <span>(Details : {SNOMED CT code '368209003' = 'Right upper arm', given as 'Right arm'})</span></p><blockquote><p><b>component</b></p><p><b>code</b>: Systolic blood pressure <span>(Details : {LOINC code '8480-6' = 'Systolic blood pressure', given as 'Systolic blood pressure'}; {SNOMED CT code '271649006' = 'Systolic blood pressure', given as 'Systolic blood pressure'}; {http://acme.org/devices/clinical-codes code 'bp-s' = 'bp-s', given as 'Systolic Blood pressure'})</span></p><p><b>value</b>: 107 mmHg<span> (Details: UCUM code mm[Hg] = 'mmHg')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span>(Details : {LOINC code '8462-4' = 'Diastolic blood pressure', given as 'Diastolic blood pressure'})</span></p><p><b>dataAbsentReason</b>: Not Performed <span>(Details : {http://terminology.hl7.org/CodeSystem/data-absent-reason code 'not-performed' = 'Not Performed', given as 'Not Performed'})</span></p></blockquote></div>" }, "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" } ], "status": "final", "category": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/observation-category", "code": "vital-signs", "display": "Vital Signs" } ] } ], "code": { "coding": [ { "system": "http://loinc.org", "code": "85354-9", "display": "Blood pressure panel with all children optional" } ], "text": "Blood pressure systolic & diastolic" }, "subject": { "reference": "Patient/example" }, "effectiveDateTime": "2012-09-17", "performer": [ { "reference": "Practitioner/example" } ], "interpretation": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation", "code": "L", "display": "low" } ], "text": "Below low normal" } ], "bodySite": { "coding": [ { "system": "http://snomed.info/sct", "code": "368209003", "display": "Right arm" } ] }, "component": [ { "code": { "coding": [ { "system": "http://loinc.org", "code": "8480-6", "display": "Systolic blood pressure" }, { "system": "http://snomed.info/sct", "code": "271649006", "display": "Systolic blood pressure" }, { "system": "http://acme.org/devices/clinical-codes", "code": "bp-s", "display": "Systolic Blood pressure" } ] }, "valueQuantity": { "value": 107, "unit": "mmHg", "system": "http://unitsofmeasure.org", "code": "mm[Hg]" } }, { "code": { "coding": [ { "system": "http://loinc.org", "code": "8462-4", "display": "Diastolic blood pressure" } ] }, "dataAbsentReason": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/data-absent-reason", "code": "not-performed", "display": "Not Performed" } ] } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.