R6 Ballot (1st Draft)

This page is part of the FHIR Specification v6.0.0-ballot1: Release 6 Ballot (1st Draft) (see Ballot Notes). The current version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example StructureDefinition/example-section-library (Narrative)

FHIR Infrastructure Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile StructureDefinition.


Generated Narrative: StructureDefinition

Resource StructureDefinition "example-section-library"

StructureDefinition Work Group: fhir

url: http://hl7.org/fhir/StructureDefinition/example-section-library

identifier: id: #urn:oid:2.16.840.1.113883.4.642.5.1041

name: DocumentSectionLibrary

title: Document Section Library (For testing section templates)

status: active

experimental: false

date: 2018-11-05T17:57:00+11:00

publisher: HL7 International / FHIR Infrastructure

contact:

description: Document Section Library (For testing section templates)

kind: resource

abstract: true

type: Composition

baseDefinition: Composition

derivation: constraint

differential

element

path: Composition

element

path: Composition.section

slicing

element

path: Composition.section

sliceName: procedure

element

path: Composition.section.title

min: 1

fixed: Procedures Performed

element

path: Composition.section.code

min: 1

pattern: Procedure Narrative (LOINC#29554-3)

element

path: Composition.section

sliceName: medications

element

path: Composition.section.title

min: 1

fixed: Medications Administered

element

path: Composition.section.code

min: 1

pattern: Medication administered Narrative (LOINC#29549-3)

element

path: Composition.section

sliceName: plan

element

path: Composition.section.title

min: 1

fixed: Discharge Treatment Plan

element

path: Composition.section.code

min: 1

pattern: Plan of treatment (narrative) (LOINC#18776-5)


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.