R6 Ballot (1st Draft)

This page is part of the FHIR Specification v6.0.0-ballot1: Release 6 Ballot (1st Draft) (see Ballot Notes). The current version is 5.0.0. For a full list of available versions, see the Directory of published versions

Example Device/KinsaThermometer (JSON)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw JSON (canonical form + also see JSON Format Specification)

KinsaThermometer

{
  "resourceType" : "Device",
  "id" : "KinsaThermometer",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"KinsaThermometer\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;KinsaThermometer&quot; </p></div><p><b>identifier</b>: System Identifier:\u00a000-00-52-49-20-45-4C-42, Bluetooth Address:\u00a010-CE-A9-80-14-66</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td style=\"display: none\">*</td><td>18479793050726</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)18479793050726(21)1i9JfKh</td><td>unknown</td></tr></table><p><b>manufacturer</b>: Kinsa</p><p><b>serialNumber</b>: 1i9JfKh</p><h3>Names</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>KS_1i9JfKh</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: KS_1i9JfKh</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: 1.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: V2.19</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 1.00</p></blockquote><h3>ConformsTos</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Specification</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528392)</span></td><td>1</td></tr></table><h3>Properties</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Type</b></td><td><b>Value[x]</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></td><td>MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.4.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></td></tr></table></div>"
  },
  "identifier" : [{
    "type" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
        "code" : "SYSID",
        "display" : "System Identifier"
      }]
    },
    "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
    "value" : "00-00-52-49-20-45-4C-42"
  },
  {
    "type" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
        "code" : "BTMAC",
        "display" : "Bluetooth Address"
      }]
    },
    "system" : "http://hl7.org/fhir/sid/eui-48",
    "value" : "10-CE-A9-80-14-66"
  }],
  "udiCarrier" : [{
    "deviceIdentifier" : "18479793050726",
    "issuer" : "http://hl7.org/fhir/NamingSystem/gs1-di",
    "jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi",
    "carrierHRF" : "(01)18479793050726(21)1i9JfKh",
    "entryType" : "unknown"
  }],
  "manufacturer" : "Kinsa",
  "serialNumber" : "1i9JfKh",
  "name" : [{
    "value" : "KS_1i9JfKh",
    "type" : "user-friendly-name"
  }],
  "modelNumber" : "KS_1i9JfKh",
  "type" : [{
    "coding" : [{
      "system" : "urn:iso:std:iso:11073:10101",
      "code" : "65573",
      "display" : "MDC_MOC_VMS_MDS_SIMP"
    }],
    "text" : "MDC_MOC_VMS_MDS_SIMP: Personal Health Device"
  }],
  "version" : [{
    "type" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "531976"
      }],
      "text" : "MDC_ID_PROD_SPEC_FW: Firmware revision"
    },
    "value" : "1.00"
  },
  {
    "type" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "531975"
      }],
      "text" : "MDC_ID_PROD_SPEC_SW: Software revision"
    },
    "value" : "V2.19"
  },
  {
    "type" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "531974"
      }],
      "text" : "MDC_ID_PROD_SPEC_SW: Hardware revision"
    },
    "value" : "1.00"
  }],
  "conformsTo" : [{
    "specification" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "528392"
      }],
      "text" : "MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"
    },
    "version" : "1"
  }],
  "property" : [{
    "type" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "68220"
      }],
      "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "532224"
      }],
      "text" : "MDC_TIME_SYNC_NONE: No time synchronization"
    }
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.