This page is part of the FHIR Specification v6.0.0-ballot1: Release 6 Ballot (1st Draft) (see Ballot Notes). The current version is 5.0.0. For a full list of available versions, see the Directory of published versions
Security Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Converted ATNA message from a PIX query (id = "example-pixQuery")
<?xml version="1.0" encoding="UTF-8"?> <AuditEvent xmlns="http://hl7.org/fhir"> <id value="example-pixQuery"/> <text> <status value="extensions"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: AuditEvent</b> <a name="example-pixQuery"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource AuditEvent "example-pixQuery" </p> </div> <p> <b> category</b> : Query <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://dicom.nema.org/resources/ontology/DCM">DICOM</a> #110112)</span> </p> <p> <b> code</b> : PIX Query <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (unknown#ITI-9)</span> </p> <p> <b> action</b> : E</p> <p> <b> recorded</b> : 27 Aug 2015, 9:42:24 am</p> <h3> Outcomes</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> Code</b> </td> </tr> <tr> <td style="display: none">*</td> <td> Success (Details: http://terminology.hl7.org/CodeSystem/audit-event-outcome code 0 = 'Success', stated as 'Success')</td> </tr> </table> <blockquote> <p> <b> agent</b> </p> <p> <b> AuditEvent Alternative User ID</b> : process ID: 6580</p> <p> <b> type</b> : Source Role ID <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://dicom.nema.org/resources/ontology/DCM">DICOM</a> #110153)</span> </p> <p> <b> who</b> : <span> id: 2.16.840.1.113883.4.2</span> </p> <p> <b> requestor</b> : false</p> <p> <b> network</b> : Workstation1.ehr.familyclinic.com</p> </blockquote> <blockquote> <p> <b> agent</b> </p> <p> <b> type</b> : <span title=" The Human using the software, if known ">human user <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.4.0/CodeSystem-extra-security-role-type.html">Security Role Type</a> #humanuser)</span> </span> </p> <p> <b> who</b> : <span> : Grahame Grieve</span> </p> <p> <b> requestor</b> : true</p> </blockquote> <h3> Sources</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> Observer</b> </td> </tr> <tr> <td style="display: none">*</td> <td> <span> : hl7connect.healthintersections.com.au</span> </td> </tr> </table> <blockquote> <p> <b> entity</b> </p> <p> <b> what</b> : <span title=" The Patient "><span> id: e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO</span> </span> </p> <p> <b> role</b> : Patient <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.4.0/CodeSystem-object-role.html">AuditEventEntityRole</a> #1)</span> </p> </blockquote> <blockquote> <p> <b> entity</b> </p> <p> <b> role</b> : <span title=" The PIX Query Parameters ">Query <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.4.0/CodeSystem-object-role.html">AuditEventEntityRole</a> #24)</span> </span> </p> <p> <b> query</b> : <span title=" The complete query message (including MSH and QPD segments), base64 encoded ">(base64 data - 1653 bytes)</span> </p> <h3> Details</h3> <table class="grid"><tr> <td style="display: none">-</td> <td> <b> Type</b> </td> <td> <b> Value[x]</b> </td> </tr> <tr> <td style="display: none">*</td> <td> <span title=" MSH-10 ">MSH-10 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ([not stated]#MSH-10)</span> </span> </td> <td> (base64 data - 29 bytes)</td> </tr> </table> </blockquote> </div> </text> <category> <coding> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="110112"/> <display value="Query"/> </coding> </category> <code> <coding> <system value="urn:oid:1.3.6.1.4.1.19376.1.2"/> <code value="ITI-9"/> <display value="PIX Query"/> </coding> </code> <action value="E"/> <recorded value="2015-08-26T23:42:24Z"/> <outcome> <code> <system value="http://terminology.hl7.org/CodeSystem/audit-event-outcome"/> <code value="0"/> <display value="Success"/> </code> </outcome> <agent> <!-- Source active participant, the software making the PIX query UserId - The identity of the Patient Identifier Cross-reference Consumer Actor facility and sending application from the HL7 message; concatenated together, separated by the | character. AlternativeUserId - Process ID --> <extension url="http://hl7.org/fhir/StructureDefinition/auditevent-AlternativeUserID"> <valueIdentifier> <type> <text value="process ID"/> </type> <value value="6580"/> </valueIdentifier> </extension> <type> <coding> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="110153"/> <display value="Source Role ID"/> </coding> </type> <who> <identifier> <system value="urn:oid:2.16.840.1.113883.4.2"/> <value value="2.16.840.1.113883.4.2"/> </identifier> </who> <requestor value="false"/> <networkString value="Workstation1.ehr.familyclinic.com"/> </agent> <agent> <!-- The Human using the software, if known --> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/extra-security-role-type"/> <code value="humanuser"/> <display value="human user"/> </coding> </type> <who> <identifier> <value value="95"/> </identifier> <display value="Grahame Grieve"/> </who> <requestor value="true"/> </agent> <source> <observer> <display value="hl7connect.healthintersections.com.au"/> </observer> </source> <entity> <!-- The Patient --> <what> <identifier> <value value="e3cdfc81a0d24bd^^^&2.16.840.1.113883.4.2&ISO"/> </identifier> </what> <role> <coding> <system value="http://terminology.hl7.org/CodeSystem/object-role"/> <code value="1"/> <display value="Patient"/> </coding> </role> </entity> <entity> <!-- The PIX Query Parameters --> <role> <coding> <system value="http://terminology.hl7.org/CodeSystem/object-role"/> <code value="24"/> <display value="Query"/> </coding> </role> <!-- The complete query message (including MSH and QPD segments), base64 encoded --> <query value="PD94bWwgdmVyc2lvbj0iMS4wIiBlbmNvZGluZz0iVVRGLTgiPz4KPFBSUEFfSU4yMDEzMDlVVjAyIElUU1ZlcnNpb249I lhNTF8xLjAiIHhtbG5zPSJ1cm46aGw3LW9yZzp2MyI+CiAgPGlkIGV4dGVuc2lvbj0iMzU0MjMiIHJvb3Q9IjEuMi44NDA uMTE0MzUwLjEuMTMuMC4xLjcuMS4xIi8+CiAgPGNyZWF0aW9uVGltZSB2YWx1ZT0iMjAxNDA1MDgxNjQ5MjUiLz4KICA8a W50ZXJhY3Rpb25JZCBleHRlbnNpb249IlBSUEFfSU4yMDEzMDVVVjAyIiByb290PSIyLjE2Ljg0MC4xLjExMzg4My4xLjY iLz4KICA8cHJvY2Vzc2luZ0NvZGUgY29kZT0iVCIvPgogIDxwcm9jZXNzaW5nTW9kZUNvZGUgY29kZT0iVCIvPgogIDxhY 2NlcHRBY2tDb2RlIGNvZGU9IkFMIi8+CiAgPHJlY2VpdmVyIHR5cGVDb2RlPSJSQ1YiPgogICAgPGRldmljZSBjbGFzc0N vZGU9IkRFViIgZGV0ZXJtaW5lckNvZGU9IklOU1RBTkNFIj4KICAgICAgPGlkIHJvb3Q9IkVIUl9NSVNZUyIvPgogICAgI CA8YXNBZ2VudCBjbGFzc0NvZGU9IkFHTlQiPgogICAgICAgIDxyZXByZXNlbnRlZE9yZ2FuaXphdGlvbiBjbGFzc0NvZGU 9Ik9SRyIgZGV0ZXJtaW5lckNvZGU9IklOU1RBTkNFIj4KICAgICAgICAgIDxpZCByb290PSJNSVNZUyIvPgogICAgICAgI DwvcmVwcmVzZW50ZWRPcmdhbml6YXRpb24+CiAgICAgIDwvYXNBZ2VudD4KICAgIDwvZGV2aWNlPgogIDwvcmVjZWl2ZXI +CiAgPHNlbmRlciB0eXBlQ29kZT0iU05EIj4KICAgIDxkZXZpY2UgY2xhc3NDb2RlPSJERVYiIGRldGVybWluZXJDb2RlP SJJTlNUQU5DRSI+CiAgICAgIDxpZCByb290PSIyLjE2Ljg0MC4xLjExMzg4My40LjIiLz4KICAgICAgPGFzQWdlbnQgY2x hc3NDb2RlPSJBR05UIj4KICAgICAgICA8cmVwcmVzZW50ZWRPcmdhbml6YXRpb24gY2xhc3NDb2RlPSJPUkciIGRldGVyb WluZXJDb2RlPSJJTlNUQU5DRSI+CiAgICAgICAgICA8aWQgcm9vdD0iMi4xNi44NDAuMS4xMTM4ODMuNC4yIi8+CiAgICA gICAgPC9yZXByZXNlbnRlZE9yZ2FuaXphdGlvbj4KICAgICAgPC9hc0FnZW50PgogICAgPC9kZXZpY2U+CiAgPC9zZW5kZ XI+CiAgPGNvbnRyb2xBY3RQcm9jZXNzIGNsYXNzQ29kZT0iQ0FDVCIgbW9vZENvZGU9IkVWTiI+CiAgICA8Y29kZSBjb2R lPSJQUlBBX1RFMjAxMzA5VVYwMiIgY29kZVN5c3RlbT0iMi4xNi44NDAuMS4xMTM4ODMuMS42Ii8+CiAgICA8cXVlcnlCe VBhcmFtZXRlcj4KICAgICAgPHF1ZXJ5SWQgZXh0ZW5zaW9uPSIxODQwOTk3MDg0IiByb290PSIxLjIuODQwLjExNDM1MC4 xLjEzLjI4LjEuMTguNS45OTkiLz4KICAgICAgPHN0YXR1c0NvZGUgY29kZT0ibmV3Ii8+CiAgICAgIDxyZXNwb25zZVBya W9yaXR5Q29kZSBjb2RlPSJJIi8+CiAgICAgIDxwYXJhbWV0ZXJMaXN0PgogICAgICAgIDxwYXRpZW50SWRlbnRpZmllcj4 KICAgICAgICAgIDx2YWx1ZSBleHRlbnNpb249IlN1cnlhQnJhbmQiIHJvb3Q9IjIuMTYuODQwLjEuMTEzODgzLjQuMiIvP gogICAgICAgICAgPHNlbWFudGljc1RleHQ+UGF0aWVudC5JZDwvc2VtYW50aWNzVGV4dD4KICAgICAgICA8L3BhdGllbnR JZGVudGlmaWVyPgogICAgICA8L3BhcmFtZXRlckxpc3Q+CiAgICA8L3F1ZXJ5QnlQYXJhbWV0ZXI+CiAgPC9jb250cm9sQ WN0UHJvY2Vzcz4KPC9QUlBBX0lOMjAxMzA5VVYwMj4K"/> <detail> <!-- MSH-10 --> <type> <coding> <code value="MSH-10"/> </coding> </type> <valueBase64Binary value="MS4yLjg0MC4xMTQzNTAuMS4xMy4wLjEuNy4xLjE="/> </detail> </entity> </AuditEvent>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot1 generated on Mon, Dec 18, 2023 15:16+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change