This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Order for mechanical ventilation with order details
{ "resourceType": "ServiceRequest", "id": "vent", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>code</b>: <span>Mechanical Ventilation</span></p><p><b>orderDetail</b>: <span>IPPB</span>, <span> Initial Settings : Sens: -1 cm H20 Pressure 15 cm H2O moderate flow: Monitor VS every 15 minutes x 4 at the start of mechanical ventilation, then routine for unit OR every 5 hr</span></p><p><b>subject</b>: <a>Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>authoredOn</b>: 2018-02-20</p><p><b>requester</b>: <a>Dr. Beverly Crusher. Generated Summary: </a></p><p><b>performer</b>: <a>Dr Cecil Surgeon. Generated Summary: id: 23; active; Adam Careful </a></p><h3>Reasons</h3><table><tr><td>-</td></tr><tr><td>*</td></tr></table></div>" }, "status": "completed", "intent": "order", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "40617009", "display": "Artificial respiration (procedure)" } ], "text": "Mechanical Ventilation" }, "orderDetail": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "243144002", "display": "Patient triggered inspiratory assistance (procedure)" } ], "text": "IPPB" }, { "text": " Initial Settings : Sens: -1 cm H20 Pressure 15 cm H2O moderate flow: Monitor VS every 15 minutes x 4 at the start of mechanical ventilation, then routine for unit OR every 5 hr" } ], "subject": { "reference": "Patient/example" }, "authoredOn": "2018-02-20", "requester": { "reference": "Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809", "display": "Dr. Beverly Crusher" }, "performer": [ { "reference": "Practitioner/example", "display": "Dr Cecil Surgeon" } ], "reason": [ { "concept": { "text": "chronic obstructive lung disease (COLD)" } } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.