Release 5 Draft Ballot

This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Observation-example.ttl

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw Turtle (+ also see Turtle/RDF Format Specification)

Simple Weight Example

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Observation/example> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "example"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p/><p><b>category</b>: <span>Vital Signs</span></p><p><b>code</b>: <span>Body Weight</span></p><p><b>subject</b>: <a>Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a>Generated Summary: status: in-progress; <span>inpatient encounter</span></a></p><p><b>effective</b>: 2016-03-28</p><p><b>value</b>: 185 lbs</p></div>"
  ];
  fhir:Observation.status [ fhir:value "final"];
  fhir:Observation.category [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/observation-category" ];
       fhir:Coding.code [ fhir:value "vital-signs" ];
       fhir:Coding.display [ fhir:value "Vital Signs" ]
     ]
  ];
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a loinc:29463-7;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "29463-7" ];
       fhir:Coding.display [ fhir:value "Body Weight" ]
     ], [
       fhir:index 1;
       a loinc:3141-9;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "3141-9" ];
       fhir:Coding.display [ fhir:value "Body weight Measured" ]
     ], [
       fhir:index 2;
       a sct:27113001;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "27113001" ];
       fhir:Coding.display [ fhir:value "Body weight" ]
     ], [
       fhir:index 3;
       fhir:Coding.system [ fhir:value "http://acme.org/devices/clinical-codes" ];
       fhir:Coding.code [ fhir:value "body-weight" ];
       fhir:Coding.display [ fhir:value "Body Weight" ]
     ]
  ];
  fhir:Observation.subject [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ];
  fhir:Observation.encounter [
     fhir:link <http://hl7.org/fhir/Encounter/example>;
     fhir:Reference.reference [ fhir:value "Encounter/example" ]
  ];
  fhir:Observation.effectiveDateTime [ fhir:value "2016-03-28"^^xsd:date];
  fhir:Observation.valueQuantity [
     fhir:Quantity.value [ fhir:value "185"^^xsd:decimal ];
     fhir:Quantity.unit [ fhir:value "lbs" ];
     fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
     fhir:Quantity.code [ fhir:value "[lb_av]" ]
  ] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

<http://hl7.org/fhir/Encounter/example> a fhir:Encounter .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/Observation/example.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/Observation/example.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.