This page is part of the FHIR Specification (v4.6.0: R5 Draft Ballot). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner |
Raw JSON (canonical form + also see JSON Format Specification)
Nutrition Order Enteral Continuous Feeding Example
{ "resourceType": "NutritionOrder", "id": "enteralcontinuous", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>identifier</b>: id: 123</p><p><b>status</b>: active</p><p><b>intent</b>: order</p><p><b>patient</b>: <a>Peter Chalmers. Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a>Inpatient. Generated Summary: status: in-progress; <span>inpatient encounter</span></a></p><p><b>dateTime</b>: 2014-09-17</p><p><b>orderer</b>: <a>Dr Adam Careful. Generated Summary: id: 23; active; Adam Careful </a></p><blockquote><p><b>enteralFormula</b></p><p><b>baseFormulaType</b>: <span>Diabetic specialty enteral formula</span></p><p><b>baseFormulaProductName</b>: Acme Diabetes Formula</p><p><b>caloricDensity</b>: 1 calories per milliliter</p><p><b>routeofAdministration</b>: <span>Instillation, nasogastric tube</span></p><blockquote><p><b>administration</b></p><p><b>schedule</b>: Starting 17 Sep. 2014, 5:00:00 pm, Do Once</p><p><b>rate</b>: 60 ml/hr</p></blockquote><blockquote><p><b>administration</b></p><p><b>schedule</b>: Starting 17 Sep. 2014, 9:00:00 pm, Do Once</p><p><b>rate</b>: 80 ml/hr</p></blockquote><blockquote><p><b>administration</b></p><p><b>schedule</b>: Starting 18 Sep. 2014, 1:00:00 am, Do Once</p><p><b>rate</b>: 100 ml/hr</p></blockquote><p><b>maxVolumeToDeliver</b>: 880 milliliter/day</p><p><b>administrationInstruction</b>: Hold feedings from 7 pm to 7 am. Add MCT oil to increase calories from 1.0 cal/mL to 1.5 cal/mL</p></blockquote></div>" }, "identifier": [ { "system": "http://www.acme.org/nutritionorders", "value": "123" } ], "status": "active", "intent": "order", "patient": { "reference": "Patient/example", "display": "Peter Chalmers" }, "encounter": { "reference": "Encounter/example", "display": "Inpatient" }, "dateTime": "2014-09-17", "orderer": { "reference": "Practitioner/example", "display": "Dr Adam Careful" }, "enteralFormula": { "baseFormulaType": { "coding": [ { "system": "http://snomed.info/sct", "code": "6547210000124112", "display": "Diabetic specialty enteral formula" } ] }, "baseFormulaProductName": " Acme Diabetes Formula", "caloricDensity": { "value": 1, "unit": "calories per milliliter", "system": "http://unitsofmeasure.org", "code": "cal/mL" }, "routeofAdministration": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v3-RouteOfAdministration", "code": "NGT", "display": "Instillation, nasogastric tube" } ] }, "administration": [ { "schedule": { "repeat": { "boundsPeriod": { "start": "2014-09-17T07:00:00Z" } } }, "rateQuantity": { "value": 60, "unit": "ml/hr", "system": "http://unitsofmeasure.org", "code": "mL/h" } }, { "schedule": { "repeat": { "boundsPeriod": { "start": "2014-09-17T11:00:00Z" } } }, "rateQuantity": { "value": 80, "unit": "ml/hr", "system": "http://unitsofmeasure.org", "code": "mL/h" } }, { "schedule": { "repeat": { "boundsPeriod": { "start": "2014-09-17T15:00:00Z" } } }, "rateQuantity": { "value": 100, "unit": "ml/hr", "system": "http://unitsofmeasure.org", "code": "mL/h" } } ], "maxVolumeToDeliver": { "value": 880, "unit": "milliliter/day", "system": "http://unitsofmeasure.org", "code": "mL/d" }, "administrationInstruction": "Hold feedings from 7 pm to 7 am. Add MCT oil to increase calories from 1.0 cal/mL to 1.5 cal/mL" } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.