This page is part of the FHIR Specification (v4.1.0: Release 4B Ballot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile SpecimenDefinition.
Generated Narrative
typeCollected: Venous blood specimen
patientPreparation: 12 hour fasting, At rest
timeAspect: preferrably morning time
typeTested
type: Serum specimen
preference: preferred
Containers
- Material Type Cap MinimumVolume[x] * plastic Evacuated blood collection tube, thrombin/clot activator/gel separator yellow cap 2 ml handling
temperatureQualifier: Ambient temperature
temperatureRange: 15-25 °C
MaxDurations
- * handling
temperatureQualifier: Refrigerated temperature
temperatureRange: 2-8 °C
MaxDurations
- *
typeTested
type: Plasma specimen
preference: alternate
Containers
- Material Type Cap MinimumVolume[x] * glass Evacuated blood collection tube with heparin lithium and gel separator green cap 2 ml rejectionCriterion: insufficient specimen volume, hemolized specimen
handling
temperatureQualifier: Ambient temperature
temperatureRange: 15-25 °C
MaxDurations
- * handling
temperatureQualifier: Refrigerated temperature
temperatureRange: 2-8 °C
MaxDurations
- *
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.