This page is part of the FHIR Specification (v4.1.0: Release 4B Ballot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
An example to demonstrate using the bodyPosition and delta extensions
{ "resourceType": "Observation", "id": "map-sitting", "text": { "status": "extensions", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>bodyPosition</b>: <span>Sitting position (finding)</span></p><p><b>delta</b>: <span>Decreased (qualifier value)</span></p><p/><p><b>category</b>: <span>Laboratory</span></p><p><b>code</b>: <span>Mean blood pressure</span></p><p><b>subject</b>: <a>Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a>Generated Summary: status: in-progress; <span>inpatient encounter</span></a></p><p><b>effective</b>: 2 Apr. 2018, 7:30:10 pm --> 5 Apr. 2018, 7:30:10 pm</p><p><b>issued</b>: 4 Apr. 2018, 12:30:10 am</p><p><b>value</b>: 60 mm Hg</p><p><b>interpretation</b>: <span>Below low normal</span></p></div>" }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition", "valueCodeableConcept": { "coding": [ { "system": "http://snomed.info/sct", "code": "33586001", "display": "Sitting position (finding)" } ] } }, { "url": "http://hl7.org/fhir/StructureDefinition/observation-delta", "valueCodeableConcept": { "coding": [ { "system": "http://snomed.info/sct", "code": "1250004", "display": "Decreased (qualifier value)" } ] } } ], "status": "final", "category": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/observation-category", "code": "laboratory", "display": "Laboratory" } ] } ], "code": { "coding": [ { "system": "http://loinc.org", "code": "8478-0", "display": "Mean blood pressure" } ] }, "subject": { "reference": "Patient/example" }, "encounter": { "reference": "Encounter/example" }, "effectivePeriod": { "start": "2018-04-02T10:30:10+01:00", "end": "2018-04-05T10:30:10+01:00" }, "issued": "2018-04-03T15:30:10+01:00", "valueQuantity": { "value": 60, "unit": "mm Hg", "system": "http://unitsofmeasure.org", "code": "mm[Hg]" }, "interpretation": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v2-0078", "code": "L", "display": "Low" } ], "text": "Below low normal" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.