Release 4B Ballot #1

This page is part of the FHIR Specification (v4.1.0: Release 4B Ballot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f206-staphylococcus.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Real-world patient - staphylococcus (id = "f206")

<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="f206"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p/>  <p> <b> code</b> : <span> Blood culture</span> </p> <p> <b> subject</b> : <a> Roel. Generated Summary: BSN: 123456789 (OFFICIAL), BSN: 123456789 (OFFICIAL); active;
           Roel(OFFICIAL); Phone: +31612345678, Phone: +31201234567; gender: male; birthDate: 1960-03-13;
           <span> Legally married</span> ; </a> </p> <p> <b> issued</b> : 11 Mar. 2013, 8:28:00 pm</p> <p> <b> performer</b> : <a> Luigi Maas. Generated Summary: UZI-nummer: 12345678902 (OFFICIAL), BIG-nummer: 12345678902
           (OFFICIAL); active; Luigi Maas(OFFICIAL); Phone: +31715269111; gender: male; birthDate:
           1960-06-12</a> </p> <p> <b> value</b> : <span> Staphylococcus aureus</span> </p> <p> <b> interpretation</b> : <span> Positive</span> </p> <p> <b> method</b> : <span> Blood culture for bacteria, including anaerobic screen</span> </p> </div> </text> <status value="final"/> 
  <code> <!--    Kind of observation = Blood culture    --><coding> 
      <system value="http://acmelabs.org"/> 
      <code value="104177"/> 
      <display value="Blood culture"/> 
    </coding> 
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="600-7"/> 
      <display value="Bacteria identified in Blood by Culture"/> 
    </coding> 
  </code> <!--    No identifier could be provided to this observation    --><subject> 
    <reference value="Patient/f201"/> 
    <display value="Roel"/> 
  </subject> 
  <issued value="2013-03-11T10:28:00+01:00"/> 
  <performer> 
    <reference value="Practitioner/f202"/> 
    <display value="Luigi Maas"/> 
  </performer> 
  <valueCodeableConcept> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="3092008"/> 
      <display value="Staphylococcus aureus"/> 
    </coding> 
  </valueCodeableConcept> 
  <interpretation> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> 
      <code value="POS"/> 
    </coding> 
  </interpretation> <!--    BodySite not relevant    --><method> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="104177005"/> 
      <display value="Blood culture for bacteria, including anaerobic screen"/> 
    </coding> 
  </method> <!--    ReferenceRange and component are not applicable    --></Observation> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.