Release 4B Ballot #1

This page is part of the FHIR Specification (v4.1.0: Release 4B Ballot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Observation-example-body-length.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Simple Body Length Example (id = "body-length")

<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="body-length"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/> 
  </meta> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <p/>  <p> <b> category</b> : <span> Vital Signs</span> </p> <p> <b> code</b> : <span> Body Length</span> </p> <p> <b> subject</b> : <a> Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers
           (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410
           5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a> </p> <p> <b> effective</b> : 1999-07-02</p> <p> <b> value</b> : 25 cm</p> </div> </text> <status value="final"/> 
  <category> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/observation-category"/> 
      <code value="vital-signs"/> 
      <display value="Vital Signs"/> 
    </coding> 
    <text value="Vital Signs"/> 
  </category> 
  <!--     This example demonstrates the use of a code translation to allow the observation to
   be interpreted as Body Length  ( typically used for infants)     -->
  <code> 
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="8302-2"/> 
      <display value="Body height"/> 
    </coding> 
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="8306-3"/> 
      <display value="Body height --lying"/> 
      <userSelected value="true"/> 
    </coding> 
    <text value="Body Length"/> 
  </code> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <effectiveDateTime value="1999-07-02"/> 
  <valueQuantity> 
    <value value="25"/> 
    <unit value="cm"/> 
    <system value="http://unitsofmeasure.org"/> 
    <code value="cm"/> 
  </valueQuantity> 
</Observation> 