Release 4B Ballot #1

This page is part of the FHIR Specification (v4.1.0: Release 4B Ballot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationexample0305.ttl

Pharmacy Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw Turtle (+ also see Turtle/RDF Format Specification)

Eye Drop Example - Manufactured Product - Timoptic

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Medication/med0305> a fhir:Medication;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "med0305"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>code</b>: <span>Timoptic 5mg/ml solution</span></p><p><b>manufacturer</b>: <a> </a></p><blockquote><p><b>name</b>: Aton Pharma Inc</p></blockquote><p><b>form</b>: <span>Opthalmic Solution (qualifier value)</span></p><h3>Ingredients</h3><table><tr><td>-</td><td><b>Item[x]</b></td><td><b>Strength</b></td></tr><tr><td>*</td><td><span>Timolol Maleate (substance)</span></td><td>5 mg/1 mL</td></tr></table><h3>Batches</h3><table><tr><td>-</td><td><b>LotNumber</b></td><td><b>ExpirationDate</b></td></tr><tr><td>*</td><td>9494788</td><td>2017-05-22</td></tr></table></div>"
  ];
  fhir:DomainResource.contained [
     a fhir:Organization;
     fhir:index 0;
     fhir:Resource.id [ fhir:value "org5" ];
     fhir:Organization.name [ fhir:value "Aton Pharma Inc" ]
  ];
  fhir:Medication.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
       fhir:Coding.code [ fhir:value "24208-813-10" ];
       fhir:Coding.display [ fhir:value "Timoptic 5mg/ml solution" ]
     ]
  ];
  fhir:Medication.manufacturer [
     fhir:Reference.reference [ fhir:value "#org5" ]
  ];
  fhir:Medication.form [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:75359005;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "75359005" ];
       fhir:Coding.display [ fhir:value "Opthalmic Solution (qualifier value)" ]
     ]
  ];
  fhir:Medication.ingredient [
     fhir:index 0;
     fhir:Medication.ingredient.itemCodeableConcept [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:75359005;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "75359005" ];
         fhir:Coding.display [ fhir:value "Timolol Maleate (substance)" ]
       ]
     ];
     fhir:Medication.ingredient.strength [
       fhir:Ratio.numerator [
         fhir:Quantity.value [ fhir:value "5"^^xsd:decimal ];
         fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
         fhir:Quantity.code [ fhir:value "mg" ]
       ];
       fhir:Ratio.denominator [
         fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ];
         fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
         fhir:Quantity.code [ fhir:value "mL" ]
       ]
     ]
  ];
  fhir:Medication.batch [
     fhir:Medication.batch.lotNumber [ fhir:value "9494788" ];
     fhir:Medication.batch.expirationDate [ fhir:value "2017-05-22"^^xsd:date ]
  ] .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/Medication/med0305.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/Medication/med0305.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.