Release 4B Ballot #1

This page is part of the FHIR Specification (v4.1.0: Release 4B Ballot #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Guidanceresponse-example.ttl

Clinical Decision Support Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw Turtle (+ also see Turtle/RDF Format Specification)

Example of guidanceresponse

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/GuidanceResponse/example> a fhir:GuidanceResponse;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "example"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>requestIdentifier</b>: id: guidanceRequest1</p><p><b>identifier</b>: id: guidanceResponse1</p><p><b>module</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a>Generated Summary: Medical record number: 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim , Peter James Windsor (MAIDEN); , Phone: (03) 5555 6473, Phone: (03) 3410 5613, Phone: (03) 5555 8834; gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a>Generated Summary: status: in-progress; <span>inpatient encounter</span></a></p><p><b>occurrenceDateTime</b>: 11 Mar. 2017, 3:02:00 am</p><p><b>performer</b>: <a>Device/software</a></p><p><b>reasonCode</b>: <span>Guideline Appropriate Ordering Assessment</span></p><p><b>outputParameters</b>: <a> </a></p><blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: <span>CT, head, wo iv contrast</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a>Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>"
  ];
  fhir:DomainResource.contained [
     a fhir:Parameters;
     fhir:index 0;
     fhir:Resource.id [ fhir:value "outputParameters1" ];
     fhir:Parameters.parameter [
       fhir:index 0;
       fhir:Parameters.parameter.name [ fhir:value "score" ];
       fhir:Parameters.parameter.valueDecimal [ fhir:value "7"^^xsd:decimal ]
     ], [
       fhir:index 1;
       fhir:Parameters.parameter.name [ fhir:value "item-assessed" ];
       fhir:Parameters.parameter.valueCodeableConcept [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           fhir:Coding.system [ fhir:value "http://www.ama-assn.org/go/cpt" ];
           fhir:Coding.code [ fhir:value "70450" ];
           fhir:Coding.display [ fhir:value "CT, head, wo iv contrast" ]
         ]
       ]
     ], [
       fhir:index 2;
       fhir:Parameters.parameter.name [ fhir:value "device" ];
       fhir:Parameters.parameter.valueReference [
         fhir:link <http://hl7.org/fhir/Device/software>;
         fhir:Reference.reference [ fhir:value "Device/software" ]
       ]
     ], [
       fhir:index 3;
       fhir:Parameters.parameter.name [ fhir:value "guideline-followed" ];
       fhir:Parameters.parameter.valueUri [ fhir:value "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html" ]
     ]
  ];
  fhir:GuidanceResponse.requestIdentifier [
     fhir:Identifier.system [ fhir:value "http://example.org" ];
     fhir:Identifier.value [ fhir:value "guidanceRequest1" ]
  ];
  fhir:GuidanceResponse.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "http://example.org" ];
     fhir:Identifier.value [ fhir:value "guidanceResponse1" ]
  ];
  fhir:GuidanceResponse.moduleUri [ fhir:value "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"];
  fhir:GuidanceResponse.status [ fhir:value "success"];
  fhir:GuidanceResponse.subject [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ];
  fhir:GuidanceResponse.encounter [
     fhir:link <http://hl7.org/fhir/Encounter/example>;
     fhir:Reference.reference [ fhir:value "Encounter/example" ]
  ];
  fhir:GuidanceResponse.occurrenceDateTime [ fhir:value "2017-03-10T16:02:00Z"^^xsd:dateTime];
  fhir:GuidanceResponse.performer [
     fhir:link <http://hl7.org/fhir/Device/software>;
     fhir:Reference.reference [ fhir:value "Device/software" ]
  ];
  fhir:GuidanceResponse.reasonCode [
     fhir:index 0;
     fhir:CodeableConcept.text [ fhir:value "Guideline Appropriate Ordering Assessment" ]
  ];
  fhir:GuidanceResponse.outputParameters [
     fhir:Reference.reference [ fhir:value "#outputParameters1" ]
  ] .

<http://hl7.org/fhir/Device/software> a fhir:Device .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

<http://hl7.org/fhir/Encounter/example> a fhir:Encounter .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/GuidanceResponse/example.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/GuidanceResponse/example.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.