Release 5 Preview #1

This page is part of the FHIR Specification (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0174.cs.json

Vocabulary Work GroupMaturity Level: N/AStandards Status: Informative

Raw JSON (canonical form + also see JSON Format Specification)

FHIR Value set/code system definition for HL7 v2 table 0174 ( NATURE OF TEST/OBSERVATION)

{
  "resourceType" : "CodeSystem",
  "id" : "v2-0174",
  "meta" : {
    "profile" : ["http://hl7.org/fhir/StructureDefinition/shareablecodesystem"]
  },
  "language" : "en",
  "text" : {
    "status" : "additional",
    "div" : "<div>!-- Snipped for Brevity --></div>"
  },
  "extension" : [{
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
    "valueCode" : "external"
  },
  {
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
    "valueInteger" : 0
  }],
  "url" : "http://terminology.hl7.org/CodeSystem/v2-0174",
  "identifier" : [{
    "system" : "urn:ietf:rfc:3986",
    "value" : "urn:oid:2.16.840.1.113883.18.90"
  }],
  "version" : "2.9",
  "name" : "v2.0174",
  "title" : "v2 NATURE OF TEST/OBSERVATION",
  "status" : "active",
  "experimental" : false,
  "publisher" : "HL7, Inc",
  "contact" : [{
    "telecom" : [{
      "system" : "url",
      "value" : "http://hl7.org"
    }]
  }],
  "description" : "FHIR Value set/code system definition for HL7 v2 table 0174 ( NATURE OF TEST/OBSERVATION)",
  "content" : "complete",
  "concept" : [{
    "extension" : [{
      "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments",
      "valueString" : "can be associated with one or more OM4 (specimen) segments\r\na single direct observation and would usually be associated with an OM2 and/or OM3 segments",
      "_valueString" : {
        "extension" : [{
          "extension" : [{
            "url" : "lang",
            "valueCode" : "nl"
          },
          {
            "url" : "content",
            "valueString" : "kan worden gekoppeld met een of meer OM4 (monster) segmenten. Een enkelvoudige, directe observatie en wordt meestal gekoppeld met een OM2 en/of OM3-segment"
          }],
          "url" : "http://hl7.org/fhir/StructureDefinition/translation"
        }]
      }
    }],
    "code" : "A",
    "display" : "Atomic service/test/observation (test code or treatment code)",
    "designation" : [{
      "language" : "de",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Einzeluntersuchung"
    },
    {
      "language" : "nl",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Atomische service/test/observatie (testcode of behandelingcode)"
    }]
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments",
      "valueString" : "can be associated with one or more OM4 (specimen) segments\r\na derived quantity and would usually be associated with an OM6 segment",
      "_valueString" : {
        "extension" : [{
          "extension" : [{
            "url" : "lang",
            "valueCode" : "nl"
          },
          {
            "url" : "content",
            "valueString" : "kan worden gekoppeld met een of meer OM4 (monster) segmenten. Een afgeleide hoeveelheid en wordt meestal gekoppeld met een OM6 segment"
          }],
          "url" : "http://hl7.org/fhir/StructureDefinition/translation"
        }]
      }
    }],
    "code" : "C",
    "display" : "Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output)",
    "designation" : [{
      "language" : "de",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Berechnetes Einzelergebnis"
    },
    {
      "language" : "nl",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)"
    }]
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments",
      "valueString" : "can be associated with one or more OM4 (specimen) segments\r\nSee comment for value S",
      "_valueString" : {
        "extension" : [{
          "extension" : [{
            "url" : "lang",
            "valueCode" : "nl"
          },
          {
            "url" : "content",
            "valueString" : "kan worden gekoppeld met een of meer OM4 (monster) segmenten. Zie opmerking voor waarde S"
          }],
          "url" : "http://hl7.org/fhir/StructureDefinition/translation"
        }]
      }
    }],
    "code" : "F",
    "display" : "Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens",
    "designation" : [{
      "language" : "de",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Funktionstest"
    },
    {
      "language" : "nl",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Functionele behandeling die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantietest, creatinineklaring),  meestal uitgevoerd op verschillende momenten en/of verschillende monsters"
    }]
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments",
      "valueString" : "can be associated with one or more OM4 (specimen) segments\r\nSee comment for value S",
      "_valueString" : {
        "extension" : [{
          "extension" : [{
            "url" : "lang",
            "valueCode" : "nl"
          },
          {
            "url" : "content",
            "valueString" : "kan worden gekoppeld met een of meer OM4 (monster) segmenten. Zie opmerking voor waarde S"
          }],
          "url" : "http://hl7.org/fhir/StructureDefinition/translation"
        }]
      }
    }],
    "code" : "P",
    "display" : "Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen",
    "designation" : [{
      "language" : "de",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Batterieanordnung"
    },
    {
      "language" : "nl",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster"
    }]
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/StructureDefinition/codesystem-concept-comments",
      "valueString" : "can be associated with one or more OM4 (specimen) segments\r\nCodes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements.  The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element.  In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation",
      "_valueString" : {
        "extension" : [{
          "extension" : [{
            "url" : "lang",
            "valueCode" : "nl"
          },
          {
            "url" : "content",
            "valueString" : "kan worden gekoppeld met een of meer OM4 (monster) segmenten. Codes P, F, S identificeren sets (batteries) en moeten worden gekoppeld met een OM5-segment die de lijst van elementen definieert. De definities voor de elementen in de lijst moeten worden verzonden in andere onafhankelijke OMx-segmenten, een per element. In ASTM-context worden de meeste tekstuele rapporten - zoals ontslagsamenvattingen, opnameverslagen, thoraxrapporten - beschouwd als sets, waarin elke verslagsectie (bijv. omschrijving, indruk en advies van een radiologieverslag) als aparte observatie wordt gezien."
          }],
          "url" : "http://hl7.org/fhir/StructureDefinition/translation"
        }]
      }
    }],
    "code" : "S",
    "display" : "Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b",
    "designation" : [{
      "language" : "de",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Latte von mehreren Batterieanforderungen (Aufnahmelatte)"
    },
    {
      "language" : "nl",
      "use" : {
        "system" : "http://terminology.hl7.org/CodeSystem/designation-usage",
        "code" : "display"
      },
      "value" : "Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observaties"
    }]
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.