This page is part of the FHIR Specification (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Intravenous Admixture - Potassium Chloride in D5W
{ "resourceType": "MedicationAdministration", "id": "medadmin0302", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medadmin0302</p><p><b>contained</b>: </p><p><b>partOf</b>: <a>Procedure/biopsy</a></p><p><b>status</b>: completed</p><p><b>category</b>: Inpatient <span>(Details : {http://terminology.hl7.org/CodeSystem/medication-admin-category code 'inpatient' = 'Inpatient', given as 'Inpatient'})</span></p><p><b>medication</b>: id: med0317; Injection Solution (qualifier value) <span>(Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection Solution (qualifier value)'})</span></p><p><b>subject</b>: <a>Donald Duck</a></p><p><b>encounter</b>: <a>encounter who leads to this prescription</a></p><p><b>occurence</b>: 15 Jan. 2015, 4:30:00 am --> 15 Jan. 2015, 2:30:00 pm</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Patrick Pump</a></td></tr></table><p><b>reason</b>: </p><p><b>request</b>: <a>MedicationRequest/medrx0322</a></p><h3>Dosages</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>Site</b></td><td><b>Route</b></td><td><b>Method</b></td><td><b>Dose</b></td><td><b>Rate[x]</b></td></tr><tr><td>*</td><td>KCl 20 mEq in 1 L 0.9%NS IV at 100 ml/hr</td><td>Structure of ligament of left superior vena cava <span>(Details : {SNOMED CT code '6073002' = 'Ligament of left superior vena cava', given as 'Structure of ligament of left superior vena cava'})</span></td><td>Intravenous route (qualifier value) <span>(Details : {SNOMED CT code '47625008' = 'Intravenous route', given as 'Intravenous route (qualifier value)'})</span></td><td>Continuous infusion <span>(Details )</span></td><td>20 meq<span> (Details: UCUM code meq = 'meq')</span></td><td>100 mL<span> (Details: UCUM code mL = 'mL')</span>/1 h<span> (Details: UCUM code h = 'h')</span></td></tr></table></div>" }, "contained": [ { "resourceType": "Medication", "id": "med0317", "doseForm": { "coding": [ { "system": "http://snomed.info/sct", "code": "385219001", "display": "Injection Solution (qualifier value)" } ], "text": "Injection Solution (qualifier value)" }, "ingredient": [ { "itemCodeableConcept": { "coding": [ { "system": "http://www.nlm.nih.gov/research/umls/rxnorm", "code": "204520", "display": "Potassium Chloride" } ] }, "strengthRatio": { "numerator": { "value": 2, "system": "http://unitsofmeasure.org", "code": "meq" }, "denominator": { "value": 1, "system": "http://unitsofmeasure.org", "code": "mL" } } }, { "itemCodeableConcept": { "coding": [ { "system": "http://www.nlm.nih.gov/research/umls/rxnorm", "code": "313002", "display": "Sodium Chloride 0.9% injectable solution" } ] }, "strengthRatio": { "numerator": { "value": 0.9, "system": "http://unitsofmeasure.org", "code": "g" }, "denominator": { "value": 100, "system": "http://unitsofmeasure.org", "code": "mL" } } } ] } ], "partOf": [ { "reference": "Procedure/biopsy" } ], "status": "completed", "category": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/medication-admin-category", "code": "inpatient", "display": "Inpatient" } ] } ], "medicationReference": { "reference": "#med0317" }, "subject": { "reference": "Patient/pat1", "display": "Donald Duck" }, "encounter": { "reference": "Encounter/f001", "display": "encounter who leads to this prescription" }, "occurencePeriod": { "start": "2015-01-15T04:30:00+01:00", "end": "2015-01-15T14:30:00+01:00" }, "performer": [ { "actor": { "reference": "Practitioner/f007", "display": "Patrick Pump" } } ], "reason": [ { "concept": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/reason-medication-given", "code": "b", "display": "Given as Ordered" } ] } } ], "request": { "reference": "MedicationRequest/medrx0322" }, "dosage": { "text": "KCl 20 mEq in 1 L 0.9%NS IV at 100 ml/hr", "site": { "coding": [ { "system": "http://snomed.info/sct", "code": "6073002", "display": "Structure of ligament of left superior vena cava" } ] }, "route": { "coding": [ { "system": "http://snomed.info/sct", "code": "47625008", "display": "Intravenous route (qualifier value)" } ] }, "method": { "text": "Continuous infusion" }, "dose": { "value": 20, "unit": "meq", "system": "http://unitsofmeasure.org", "code": "meq" }, "rateRatio": { "numerator": { "value": 100, "system": "http://unitsofmeasure.org", "code": "mL" }, "denominator": { "value": 1, "system": "http://unitsofmeasure.org", "code": "h" } } } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.