This page is part of the FHIR Specification (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Intravenous Antibiotic - Vancomycin
{ "resourceType": "MedicationAdministration", "id": "medadmin0301", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medadmin0301</p><p><b>contained</b>: , </p><p><b>status</b>: in-progress</p><p><b>medication</b>: id: med0301; Vancomycin Hydrochloride (VANCOMYCIN HYDROCHLORIDE) <span>(Details : {http://hl7.org/fhir/sid/ndc code '0409-6531-02' = '10 VIAL in 1 TRAY (0409-6531-02) > 1 INJECTION, POWDER, LYOPHILIZED, FOR SOLUTION in 1 VIAL', given as 'Vancomycin Hydrochloride (VANCOMYCIN HYDROCHLORIDE)'})</span></p><p><b>subject</b>: <a>Donald Duck</a></p><p><b>encounter</b>: <a>encounter who leads to this prescription</a></p><p><b>occurence</b>: 15 Jan. 2015, 2:30:00 pm --> (ongoing)</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Patrick Pump</a></td></tr></table><p><b>reason</b>: </p><p><b>request</b>: <a>MedicationRequest/medrx0318</a></p><h3>Dosages</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>Route</b></td><td><b>Method</b></td><td><b>Dose</b></td></tr><tr><td>*</td><td>500mg IV q6h x 3 days</td><td>Intravenous route (qualifier value) <span>(Details : {SNOMED CT code '47625008' = 'Intravenous route', given as 'Intravenous route (qualifier value)'})</span></td><td>IV Push <span>(Details )</span></td><td>500 mg<span> (Details: UCUM code mg = 'mg')</span></td></tr></table><p><b>eventHistory</b>: Author's Signature. Generated Summary: id: signature; recorded: 1 Feb. 2017, 5:23:07 pm; </p></div>" }, "contained": [ { "resourceType": "Medication", "id": "med0301", "code": { "coding": [ { "system": "http://hl7.org/fhir/sid/ndc", "code": "0409-6531-02", "display": "Vancomycin Hydrochloride (VANCOMYCIN HYDROCHLORIDE)" } ] } }, { "resourceType": "Provenance", "id": "signature", "target": [ { "reference": "ServiceRequest/physiotherapy" } ], "recorded": "2017-02-01T17:23:07Z", "agent": [ { "role": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/v3-ParticipationType", "code": "AUT" } ] } ], "who": { "reference": "Practitioner/example", "display": "Dr Adam Careful" } } ], "signature": [ { "type": [ { "system": "urn:iso-astm:E1762-95:2013", "code": "1.2.840.10065.1.12.1.1", "display": "Author's Signature" } ], "when": "2017-02-01T17:23:07Z", "who": { "reference": "Practitioner/example", "display": "Dr Adam Careful" }, "targetFormat": "application/fhir+xml", "sigFormat": "application/signature+xml", "data": "dGhpcyBibG9iIGlzIHNuaXBwZWQ=" } ] } ], "status": "in-progress", "medicationReference": { "reference": "#med0301" }, "subject": { "reference": "Patient/pat1", "display": "Donald Duck" }, "encounter": { "reference": "Encounter/f001", "display": "encounter who leads to this prescription" }, "occurencePeriod": { "start": "2015-01-15T14:30:00+01:00" }, "performer": [ { "actor": { "reference": "Practitioner/f007", "display": "Patrick Pump" } } ], "reason": [ { "concept": { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/reason-medication-given", "code": "b", "display": "Given as Ordered" } ] } } ], "request": { "reference": "MedicationRequest/medrx0318" }, "dosage": { "text": "500mg IV q6h x 3 days", "route": { "coding": [ { "system": "http://snomed.info/sct", "code": "47625008", "display": "Intravenous route (qualifier value)" } ] }, "method": { "text": "IV Push" }, "dose": { "value": 500, "unit": "mg", "system": "http://unitsofmeasure.org", "code": "mg" } }, "eventHistory": [ { "reference": "#signature", "display": "Author's Signature" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.