R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0472.cs.xml

Vocabulary Work GroupMaturity Level: N/ABallot Status: Informative

Raw XML (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0472 ( TQ Conjunction ID)

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="v2-0472"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/shareablecodesystem"/> 
  </meta> 
  <language value="en"/> 
  <text> 
    <status value="additional"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p> TQ Conjunction ID</p> 

      <table class="grid">
        <tr> 
          <td> 
            <b> Code</b> 
          </td> 
          <td> 
            <b> Description</b> 
          </td> 
          <td> 
            <b> Comment</b> 
          </td> 
          <td> 
            <b> Version</b> 
          </td> 
        </tr> 
        <tr> 
          <td> A
            <a name="A"> </a> 
          </td> 
          <td> Asynchronous</td> 
          <td> Do the next specification in parallel with this one (unless otherwise constrained by the
               following fields: TQ1-7-start date/time and TQ1-8-end date/time).  The conjunction of
               &quot;A&quot; specifies two parallel instructions, as are sometimes used in medication,
               e.g., prednisone given at 1 tab on Monday, Wednesday, Friday, and at 1/2 tab on Tuesday,
               Thursday, Saturday, Sunday.</td> 
          <td> added v2.4</td> 
        </tr> 
        <tr> 
          <td> C
            <a name="C"> </a> 
          </td> 
          <td> Actuation Time</td> 
          <td> It will be followed by a completion time for the service.  This code allows one to distinguish
               between the time and priority at which a service should be actuated (e.g., blood should
               be drawn) and the time and priority at which a service should be completed (e.g., results
               should be reported).</td> 
          <td> added v2.4</td> 
        </tr> 
        <tr> 
          <td> S
            <a name="S"> </a> 
          </td> 
          <td> Synchronous</td> 
          <td> Do the next specification after this one (unless otherwise constrained by the following
               fields: TQ1-7-start date/time and TQ1-8-end date/time). An &quot;S&quot; specification
               implies that the second timing sequence follows the first, e.g., when a service request
               is written to measure blood pressure Q15 minutes for the 1st hour, then every 2 hours
               for the next day.</td> 
          <td> added v2.4</td> 
        </tr> 
      </table> 

    </div> 
  </text> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status">
    <valueString value="External"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0"/> 
  </extension> 
  <url value="http://hl7.org/fhir/v2/0472"/> 
  <identifier> 
    <system value="urn:ietf:rfc:3986"/> 
    <value value="urn:oid:2.16.840.1.113883.18.300"/> 
  </identifier> 
  <version value="2.9"/> 
  <name value="v2 TQ Conjunction ID"/> 
  <status value="active"/> 
  <experimental value="false"/> 
  <publisher value="HL7, Inc"/> 
  <contact> 
    <telecom> 
      <system value="url"/> 
      <value value="http://hl7.org"/> 
    </telecom> 
  </contact> 
  <description value="FHIR Value set/code system definition for HL7 v2 table 0472 ( TQ Conjunction ID)"/> 
  <caseSensitive value="false"/> 
  <valueSet value="http://hl7.org/fhir/ValueSet/v2-0472"/> 
  <content value="complete"/> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Do the next specification in parallel with this one (unless otherwise constrained by the
         following fields: TQ1-7-start date/time and TQ1-8-end date/time).  The conjunction of
         &quot;A&quot; specifies two parallel instructions, as are sometimes used in medication,
         e.g., prednisone given at 1 tab on Monday, Wednesday, Friday, and at 1/2 tab on Tuesday,
         Thursday, Saturday, Sunday.">
        <extension url="http://hl7.org/fhir/StructureDefinition/translation">
          <extension url="lang">
            <valueString value="nl"/> 
          </extension> 
          <extension url="content">
            <valueString value="Doe de volgende specificatie parallel aan deze (tenzij anders aangegeven ion de volgende
               velden: TQ1-7-start date/time en TQ1-8-end date/time). Een specificatie &quot;A&quot;
               specificeert twee parallelle instructies, zoals soms bij medicatiedosering gebruikt, bijv.
               prednison 1 tablet op maandag, woesndag, vrijdag en een half tablet op dinsdag, donderdag,
               zaterdag en zondag."/> 
          </extension> 
        </extension> 
      </valueString> 
    </extension> 
    <code value="A"/> 
    <display value="Asynchronous"/> 
    <designation> 
      <language value="nl"/> 
      <use> 
        <system value="http://hl7.org/fhir/CodeSystem/designation-usage"/> 
        <code value="display"/> 
      </use> 
      <value value="Asynchroon"/> 
    </designation> 
  </concept> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="It will be followed by a completion time for the service.  This code allows one to distinguish
         between the time and priority at which a service should be actuated (e.g., blood should
         be drawn) and the time and priority at which a service should be completed (e.g., results
         should be reported).">
        <extension url="http://hl7.org/fhir/StructureDefinition/translation">
          <extension url="lang">
            <valueString value="nl"/> 
          </extension> 
          <extension url="content">
            <valueString value="Deze wordt gevolgd door een voltooiingstijd voor de service. Met deze code kan het verschil
               worden gemaakt tussen tijd en prioriteit waarop de service moet worden geactueerd (bijv.
               bloed moet worden afgenomen) en de tijd en prioriteit waarop de service moet zijn voltooid
               (bijv. wanneer resultaten moeten worden gemeld)."/> 
          </extension> 
        </extension> 
      </valueString> 
    </extension> 
    <code value="C"/> 
    <display value="Actuation Time"/> 
    <designation> 
      <language value="nl"/> 
      <use> 
        <system value="http://hl7.org/fhir/CodeSystem/designation-usage"/> 
        <code value="display"/> 
      </use> 
      <value value="Actuatietijd"/> 
    </designation> 
  </concept> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Do the next specification after this one (unless otherwise constrained by the following
         fields: TQ1-7-start date/time and TQ1-8-end date/time). An &quot;S&quot; specification
         implies that the second timing sequence follows the first, e.g., when a service request
         is written to measure blood pressure Q15 minutes for the 1st hour, then every 2 hours
         for the next day.">
        <extension url="http://hl7.org/fhir/StructureDefinition/translation">
          <extension url="lang">
            <valueString value="nl"/> 
          </extension> 
          <extension url="content">
            <valueString value="Doe de volgende specificatie na deze (tenzij anders aangegeven ion de volgende velden:
               TQ1-7-start date/time en TQ1-8-end date/time). Een specificatie &quot;S&quot; impliceert
               dat de tweede tijdsequentie de eerste opvolgt, bijv. als een serviceverzoek wordt gedaan
               om bloeddruk te meten Q15 minuten na het eerste uur en dan de volgende dag elke twee uur."/> 
          </extension> 
        </extension> 
      </valueString> 
    </extension> 
    <code value="S"/> 
    <display value="Synchronous"/> 
    <designation> 
      <language value="nl"/> 
      <use> 
        <system value="http://hl7.org/fhir/CodeSystem/designation-usage"/> 
        <code value="display"/> 
      </use> 
      <value value="Synchroon"/> 
    </designation> 
  </concept> 
</CodeSystem> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.