R4 Draft for Comment

This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0513.cs.xml

Vocabulary Work GroupMaturity Level: N/ABallot Status: Informative

Raw XML (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0513 ( Blood Product Transfusion/Disposition Status)

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="v2-0513"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/shareablecodesystem"/> 
  </meta> 
  <text> 
    <status value="additional"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p> Blood Product Transfusion/Disposition Status</p> 

      <table class="grid">
        <tr> 
          <td> 
            <b> Code</b> 
          </td> 
          <td> 
            <b> Description</b> 
          </td> 
          <td> 
            <b> Comment</b> 
          </td> 
          <td> 
            <b> Version</b> 
          </td> 
        </tr> 
        <tr> 
          <td> RA
            <a name="RA"> </a> 
          </td> 
          <td> Returned unused/no longer needed</td> 
          <td/>  
          <td> added v2.5</td> 
        </tr> 
        <tr> 
          <td> RL
            <a name="RL"> </a> 
          </td> 
          <td> Returned unused/keep linked to patient for possible use later</td> 
          <td/>  
          <td> added v2.5</td> 
        </tr> 
        <tr> 
          <td> TR
            <a name="TR"> </a> 
          </td> 
          <td> Transfused with adverse reaction</td> 
          <td/>  
          <td> added v2.5</td> 
        </tr> 
        <tr> 
          <td> TX
            <a name="TX"> </a> 
          </td> 
          <td> Transfused</td> 
          <td/>  
          <td> added v2.5</td> 
        </tr> 
        <tr> 
          <td> WA
            <a name="WA"> </a> 
          </td> 
          <td> Wasted (product no longer viable)</td> 
          <td/>  
          <td> added v2.5</td> 
        </tr> 
      </table> 

    </div> 
  </text> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status">
    <valueString value="External"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0"/> 
  </extension> 
  <url value="http://hl7.org/fhir/v2/0513"/> 
  <identifier> 
    <system value="urn:ietf:rfc:3986"/> 
    <value value="urn:oid:2.16.840.1.113883.18.335"/> 
  </identifier> 
  <version value="2.8.2"/> 
  <name value="v2 Blood Product Transfusion/Disposition Status"/> 
  <status value="active"/> 
  <experimental value="false"/> 
  <publisher value="HL7, Inc"/> 
  <contact> 
    <telecom> 
      <system value="url"/> 
      <value value="http://hl7.org"/> 
    </telecom> 
  </contact> 
  <description value="FHIR Value set/code system definition for HL7 v2 table 0513 ( Blood Product Transfusion/Disposition
     Status)"/> 
  <caseSensitive value="false"/> 
  <valueSet value="http://hl7.org/fhir/ValueSet/v2-0513"/> 
  <content value="complete"/> 
  <concept> 
    <code value="RA"/> 
    <display value="Returned unused/no longer needed"/> 
  </concept> 
  <concept> 
    <code value="RL"/> 
    <display value="Returned unused/keep linked to patient for possible use later"/> 
  </concept> 
  <concept> 
    <code value="TR"/> 
    <display value="Transfused with adverse reaction"/> 
  </concept> 
  <concept> 
    <code value="TX"/> 
    <display value="Transfused"/> 
  </concept> 
  <concept> 
    <code value="WA"/> 
    <display value="Wasted (product no longer viable)"/> 
  </concept> 
</CodeSystem> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.