This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Patient, Practitioner |
Pooled serum sample
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Specimen/pooled-serum> a fhir:Specimen; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "pooled-serum"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: pooled-serum</p><p><b>accessionIdentifier</b>: 20171120-1234</p><p><b>type</b>: Pooled serum sample <span>(Details : {https://vetmed.iastate.edu/vdl code 'Serum sample, pooled' = 'Serum sample, pooled', given as 'Serum sample, pooled'})</span></p><p><b>subject</b>: <a>Group/herd1</a></p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td>James Herriot, FRCVS</td><td>14/11/2017</td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Type</b></td></tr><tr><td>*</td><td>Red Top Blood Collection Tube <span>(Details : {https://vetmed.iastate.edu/vdl code 'RTT' = 'RTT', given as 'Red Top Tube'})</span></td></tr></table><p><b>note</b>: Pooled serum sample from 30 individuals</p></div>" ]; fhir:Specimen.accessionIdentifier [ fhir:Identifier.system [ fhir:value "https://vetmed.iastate.edu/vdl" ]; fhir:Identifier.value [ fhir:value "20171120-1234" ] ]; fhir:Specimen.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "https://vetmed.iastate.edu/vdl" ]; fhir:Coding.code [ fhir:value "Serum sample, pooled" ]; fhir:Coding.display [ fhir:value "Serum sample, pooled" ] ]; fhir:CodeableConcept.text [ fhir:value "Pooled serum sample" ] ]; fhir:Specimen.subject [ fhir:link <http://hl7.org/fhir/Group/herd1>; fhir:Reference.reference [ fhir:value "Group/herd1" ] ]; fhir:Specimen.collection [ fhir:Specimen.collection.collector [ fhir:Reference.display [ fhir:value "James Herriot, FRCVS" ] ]; fhir:Specimen.collection.collectedDateTime [ fhir:value "2017-11-14"^^xsd:date ] ]; fhir:Specimen.container [ fhir:index 0; fhir:Specimen.container.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "https://vetmed.iastate.edu/vdl" ]; fhir:Coding.code [ fhir:value "RTT" ]; fhir:Coding.display [ fhir:value "Red Top Tube" ] ]; fhir:CodeableConcept.text [ fhir:value "Red Top Blood Collection Tube" ] ] ]; fhir:Specimen.note [ fhir:index 0; fhir:Annotation.text [ fhir:value "Pooled serum sample from 30 individuals" ] ] . <http://hl7.org/fhir/Group/herd1> a fhir:Group . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Specimen/pooled-serum.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/Specimen/pooled-serum.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.