R4 Draft for Comment

This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f005-hemoglobin.xml

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form)

Jump past Narrative

Real-world patient - hemoglobin (id = "f005")

<Observation xmlns="http://hl7.org/fhir">
  <id value="f005"/> <!--     urn:oid:2.16.840.1.113883.4.642.1.7     --><text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : f005</p> <p> <b> identifier</b> : 6327 (OFFICIAL)</p> <p> <b> status</b> : final</p> <p> <b> code</b> : Hemoglobin [Mass/volume] in Blood <span> (Details : {LOINC code '718-7' = 'Hemoglobin [Mass/volume] in Blood', given as 'Hemoglobin
           [Mass/volume] in Blood'})</span> </p> <p> <b> subject</b> : <a> P. van de Heuvel</a> </p> <p> <b> effective</b> : 05/04/2013 10:30:10 AM --&gt; 05/04/2013 10:30:10 AM</p> <p> <b> issued</b> : 05/04/2013 3:30:10 PM</p> <p> <b> performer</b> : <a> A. Langeveld</a> </p> <p> <b> value</b> : 7.2 g/dl<span>  (Details: UCUM code g/dL = 'g/dL')</span> </p> <p> <b> interpretation</b> : Low <span> (Details : {http://hl7.org/fhir/v2/0078 code 'L' = 'Low', given as 'Low'})</span> </p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 7.5 g/dl<span>  (Details: UCUM code g/dL = 'g/dL')</span> </td> <td> 10 g/dl<span>  (Details: UCUM code g/dL = 'g/dL')</span> </td> </tr> </table> </div> </text> <identifier> 
    <use value="official"/> 
    <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/> 
    <value value="6327"/> 
  </identifier> 
  <status value="final"/> 
  <code> 
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="718-7"/> 
      <display value="Hemoglobin [Mass/volume] in Blood"/> 
    </coding> 
  </code> 
  <subject> 
    <reference value="Patient/f001"/> 
    <display value="P. van de Heuvel"/> 
  </subject> 
  <effectivePeriod> 
    <start value="2013-04-05T10:30:10+01:00"/> 
    <end value="2013-04-05T10:30:10+01:00"/> 
  </effectivePeriod> 
  <issued value="2013-04-05T15:30:10+01:00"/> 
  <performer> 
    <reference value="Practitioner/f005"/> 
    <display value="A. Langeveld"/> 
  </performer> 
  <valueQuantity> 
    <value value="7.2"/> 
    <unit value="g/dl"/> 
    <system value="http://unitsofmeasure.org"/> 
    <code value="g/dL"/> 
  </valueQuantity> 
  <interpretation> 
    <coding> 
      <system value="http://hl7.org/fhir/v2/0078"/> 
      <code value="L"/> 
      <display value="Low"/> 
    </coding> 
  </interpretation> 
  <referenceRange> 
    <low> 
      <value value="7.5"/> 
      <unit value="g/dl"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="g/dL"/> 
    </low> 
    <high> 
      <value value="10"/> 
      <unit value="g/dl"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="g/dL"/> 
    </high> 
  </referenceRange> 
</Observation> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.