R4 Draft for Comment

This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationadministration0303.xml

Pharmacy Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form)

Jump past Narrative

Intravenous Antibiotic with a Dosage Rate - Piperacillin (id = "medadmin0303")

<MedicationAdministration xmlns="http://hl7.org/fhir"> 
  <id value="medadmin0303"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : medadmin0303</p> <p> <b> contained</b> : </p> <p> <b> status</b> : entered-in-error</p> <p> <b> medication</b> : id: med0303; Zosyn (piperacillin/tazobactam) 4.5gm injection <span> (Details : {http://hl7.org/fhir/sid/ndc code '0206-8862-02' = '0206-8862-02', given as
           'Zosyn (piperacillin/tazobactam) 4.5gm injection'})</span> </p> <p> <b> subject</b> : <a> Donald Duck</a> </p> <p> <b> context</b> : <a> encounter who leads to this prescription</a> </p> <p> <b> effective</b> : 15/01/2015 4:30:00 AM --&gt; 15/01/2015 2:30:00 PM</p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a> Patrick Pump</a> </td> </tr> </table> <p> <b> request</b> : <a> MedicationRequest/medrx0319</a> </p> <h3> Dosages</h3> <table> <tr> <td> -</td> <td> <b> Text</b> </td> <td> <b> Route</b> </td> <td> <b> Dose</b> </td> <td> <b> Rate[x]</b> </td> </tr> <tr> <td> *</td> <td> 4.5 grams in D5W 250 ml. IV every 6 hours. Infuse over 30 min at 8L/min </td> <td> Intravenous route (qualifier value) <span> (Details : {SNOMED CT code '47625008' = 'Intravenous route', given as 'Intravenous route
               (qualifier value)'})</span> </td> <td> 4.5 g<span>  (Details: UCUM code g = 'g')</span> </td> <td> 8 ml<span>  (Details: UCUM code ml = 'ml')</span> /1 min<span>  (Details: UCUM code min = 'min')</span> </td> </tr> </table> </div> </text> <contained> 
      <Medication> 
        <id value="med0303"/> 
        <code> 
          <coding> 
            <system value="http://hl7.org/fhir/sid/ndc"/> 
            <code value="0206-8862-02"/> 
            <display value="Zosyn (piperacillin/tazobactam) 4.5gm injection"/> 
          </coding> 
        </code> 
      </Medication> 
  </contained> 
  <status value="entered-in-error"/> 
  <medicationReference> 
    <reference value="#med0303"/>  
  </medicationReference> 
 <subject> 
   <reference value="Patient/pat1"/> 
   <display value="Donald Duck"/>  
  </subject> 
  <context>  
    <reference value="Encounter/f001"/> 
    <display value="encounter who leads to this prescription"/> 
  </context> 
 <effectivePeriod> 
  <start value="2015-01-15T04:30:00+01:00"/> 
   <end value="2015-01-15T14:30:00+01:00"/> 
</effectivePeriod> 
  <performer> 
    <actor> <reference value="Practitioner/f007"/> 
      <display value="Patrick Pump"/> 
    </actor> 
  </performer> 
  <request> 
    <reference value="MedicationRequest/medrx0319"/> 
  </request> 
  <dosage> 
    <text value="4.5 grams in D5W 250 ml. IV every 6 hours. Infuse over 30 min at 8L/min "/> 
    <route> 
      <coding> 
        <system value="http://snomed.info/sct"/> 
        <code value="47625008"/> 
        <display value="Intravenous route (qualifier value)"/> 
      </coding> 
    </route> 
    <dose> 
      <value value="4.5"/> 
      <unit value="g"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="g"/> 
    </dose> 
    <rateRatio> 
      <numerator> 
        <value value="8"/> 
        <system value="http://unitsofmeasure.org"/> 
        <code value="ml"/> 
      </numerator> 
      <denominator> 
        <value value="1"/> 
        <system value="http://unitsofmeasure.org"/> 
        <code value="min"/> 
      </denominator> 
    </rateRatio> 
  </dosage> 
</MedicationAdministration> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.