This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner |
Abdominal Ultrasound example
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/DiagnosticReport/ultrasound> a fhir:DiagnosticReport; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "ultrasound"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: ultrasound</p><p><b>status</b>: final</p><p><b>category</b>: Radiology <span>(Details : {SNOMED CT code '394914008' = 'Radiology - speciality', given as 'Radiology'}; {http://hl7.org/fhir/v2/0074 code 'RAD' = 'Radiology)</span></p><p><b>code</b>: Abdominal Ultrasound <span>(Details : {SNOMED CT code '45036003' = 'Ultrasonography of abdomen', given as 'Ultrasonography of abdomen'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 01/12/2012 12:00:00 PM</p><p><b>issued</b>: 01/12/2012 12:00:00 PM</p><p><b>performer</b>: <a>Practitioner/example</a></p><h3>Media</h3><table><tr><td>-</td><td><b>Comment</b></td><td><b>Link</b></td></tr><tr><td>*</td><td>A comment about the image</td><td><a>WADO example image</a></td></tr></table><p><b>conclusion</b>: Unremarkable study</p></div>" ]; fhir:DiagnosticReport.status [ fhir:value "final"]; fhir:DiagnosticReport.category [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:394914008; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "394914008" ]; fhir:Coding.display [ fhir:value "Radiology" ] ], [ fhir:index 1; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0074" ]; fhir:Coding.code [ fhir:value "RAD" ] ] ]; fhir:DiagnosticReport.code [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:45036003; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "45036003" ]; fhir:Coding.display [ fhir:value "Ultrasonography of abdomen" ] ]; fhir:CodeableConcept.text [ fhir:value "Abdominal Ultrasound" ] ]; fhir:DiagnosticReport.subject [ fhir:link <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ]; fhir:DiagnosticReport.effectiveDateTime [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime]; fhir:DiagnosticReport.issued [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime]; fhir:DiagnosticReport.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Practitioner/example>; fhir:Reference.reference [ fhir:value "Practitioner/example" ] ]; fhir:DiagnosticReport.media [ fhir:index 0; fhir:DiagnosticReport.media.comment [ fhir:value "A comment about the image" ]; fhir:DiagnosticReport.media.link [ fhir:link <http://hl7.org/fhir/Media/1.2.840.11361907579238403408700.3.1.04.19970327150033>; fhir:Reference.reference [ fhir:value "Media/1.2.840.11361907579238403408700.3.1.04.19970327150033" ]; fhir:Reference.display [ fhir:value "WADO example image" ] ] ]; fhir:DiagnosticReport.conclusion [ fhir:value "Unremarkable study"] . <http://hl7.org/fhir/Patient/example> a fhir:Patient . <http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner . <http://hl7.org/fhir/Media/1.2.840.11361907579238403408700.3.1.04.19970327150033> a fhir:Media . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/DiagnosticReport/ultrasound.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/DiagnosticReport/ultrasound.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.