This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R3 R2
Health Care Devices Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device |
Example for DeviceComponent includes production specification information
{ "resourceType": "DeviceComponent", "id": "example-prodspec", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-prodspec</p><p><b>identifier</b>: 789123</p><p><b>type</b>: MDC_DEV_ANALY_SAT_O2_MDS <span>(Details : {urn:iso:std:iso:11073:10101 code '2000' = '2000', given as 'MDC_DEV_ANALY_SAT_O2_MDS'})</span></p><p><b>lastSystemChange</b>: 07/10/2014 2:45:00 PM</p><p><b>source</b>: <a>Device/d1</a></p><p><b>operationalStatus</b>: Off <span>(Details : {[not stated] code 'off' = 'off', given as 'Off'})</span></p><blockquote><p><b>productionSpecification</b></p><p><b>specType</b>: Serial number <span>(Details : {[not stated] code 'serial-number' = 'serial-number', given as 'Serial number'})</span></p><p><b>productionSpec</b>: xa-12324-b</p></blockquote><blockquote><p><b>productionSpecification</b></p><p><b>specType</b>: Hardware Revision <span>(Details : {[not stated] code 'hardware-revision' = 'hardware-revision', given as 'Hardware Revision'})</span></p><p><b>productionSpec</b>: 1.1</p></blockquote><blockquote><p><b>productionSpecification</b></p><p><b>specType</b>: Software Revision <span>(Details : {[not stated] code 'software-revision' = 'software-revision', given as 'Software Revision'})</span></p><p><b>productionSpec</b>: 1.12</p></blockquote><blockquote><p><b>productionSpecification</b></p><p><b>specType</b>: Firmware Revision <span>(Details : {[not stated] code 'firmware-revision' = 'firmware-revision', given as 'Firmware Revision'})</span></p><p><b>productionSpec</b>: 1.0.23</p></blockquote><p><b>languageCode</b>: en-US <span>(Details : {http://tools.ietf.org/html/bcp47 code 'en-US' = 'en-US)</span></p></div>" }, "identifier": [ { "value": "789123" } ], "type": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "2000", "display": "MDC_DEV_ANALY_SAT_O2_MDS" } ] }, "lastSystemChange": "2014-10-07T14:45:00Z", "source": { "reference": "Device/d1" }, "operationalStatus": [ { "coding": [ { "code": "off", "display": "Off" } ] } ], "productionSpecification": [ { "specType": { "coding": [ { "code": "serial-number", "display": "Serial number" } ] }, "productionSpec": "xa-12324-b" }, { "specType": { "coding": [ { "code": "hardware-revision", "display": "Hardware Revision" } ] }, "productionSpec": "1.1" }, { "specType": { "coding": [ { "code": "software-revision", "display": "Software Revision" } ] }, "productionSpec": "1.12" }, { "specType": { "coding": [ { "code": "firmware-revision", "display": "Firmware Revision" } ] }, "productionSpec": "1.0.23" } ], "languageCode": { "coding": [ { "system": "http://tools.ietf.org/html/bcp47", "code": "en-US" } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.