R4 Draft for Comment

This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Device-example-udi1.json

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device

Raw JSON (canonical form)

Implantable device/UDI example GS-1 Format

{
  "resourceType": "Device",
  "id": "example-udi1",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-udi1</p><p><b>identifier</b>: 1234-5678-90AB-CDEF, Serial Number = 10987654d321</p><h3>Udis</h3><table><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Name</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>CarrierAIDC</b></td><td><b>Issuer</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>00844588003288</td><td>FHIR® Hip System</td><td><a>http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>{01}00844588003288{17}141120{10}7654321D{21}10987654d321</td><td>XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH</td><td><a>http://hl7.org/fhir/NamingSystem/gs1</a></td><td>barcode</td></tr></table><p><b>status</b>: active</p><p><b>type</b>: Coated femoral stem prosthesis, modular <span>(Details : {SNOMED CT code '468063009' = 'Coated femoral stem prosthesis, modular', given as 'Coated femoral stem prosthesis, modular'})</span></p><p><b>lotNumber</b>: 7654321D</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>expirationDate</b>: 20/11/2014</p><p><b>model</b>: PM/Octane 2014</p><p><b>patient</b>: <a>Patient/example</a></p><p><b>safety</b>: MR Unsafe <span>(Details : {urn:oid:2.16.840.1.113883.3.26.1.1 code 'mr-unsafe' = 'mr-unsafe', given as 'MR Unsafe'})</span></p></div>"
  },
  "identifier": [
    {
      "system": "http://acme.com/devices/pacemakers/octane/serial",
      "value": "1234-5678-90AB-CDEF"
    },
    {
      "type": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/identifier-type",
            "code": "SNO"
          }
        ]
      },
      "value": "10987654d321"
    }
  ],
  "udi": {
    "deviceIdentifier": "00844588003288",
    "name": "FHIR® Hip System",
    "jurisdiction": "http://hl7.org/fhir/NamingSystem/fda-udi",
    "carrierHRF": "{01}00844588003288{17}141120{10}7654321D{21}10987654d321",
    "carrierAIDC": "XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH",
    "issuer": "http://hl7.org/fhir/NamingSystem/gs1",
    "entryType": "barcode"
  },
  "status": "active",
  "type": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "468063009",
        "display": "Coated femoral stem prosthesis, modular"
      }
    ],
    "text": "Coated femoral stem prosthesis, modular"
  },
  "lotNumber": "7654321D",
  "manufacturer": "Acme Devices, Inc",
  "expirationDate": "2014-11-20",
  "model": "PM/Octane 2014",
  "patient": {
    "reference": "Patient/example"
  },
  "safety": [
    {
      "coding": [
        {
          "system": "urn:oid:2.16.840.1.113883.3.26.1.1",
          "code": "mr-unsafe",
          "display": "MR Unsafe"
        }
      ],
      "text": "MR Unsafe"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.