This page is part of the FHIR Specification (v3.2.0: R4 Ballot 1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Patient Administration Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Example of chargeitem (id = "example")
<ChargeItem xmlns="http://hl7.org/fhir"> <id value="example"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml">Example of ChargeItem Usage in Context of the German EBM Billing code system</div> </text> <identifier> <system value="http://myHospital.org/ChargeItems"/> <value value="654321"/> </identifier> <definition value="http://www.kbv.de/tools/ebm/html/01520_2904360860826220813632.html"/> <status value="billable"/> <code> <coding> <code value="01510"/> <display value="Zusatzpauschale für Beobachtung nach diagnostischer Koronarangiografie"/> </coding> </code> <subject> <reference value="Patient/example"/> </subject> <context> <reference value="Encounter/example"/> </context> <occurrencePeriod> <start value="2017-01-25T08:00:00+01:00"/> <end value="2017-01-25T12:35:00+01:00"/> </occurrencePeriod> <participant> <role> <coding> <system value="http://snomed.info/sct"/> <code value="17561000"/> <display value="Cardiologist"/> </coding> </role> <actor> <reference value="Practitioner/example"/> </actor> </participant> <participant> <role> <coding> <system value="http://snomed.info/sct"/> <code value="224542009"/> <display value="Coronary Care Nurse"/> </coding> </role> <actor> <reference value="Practitioner/example"/> </actor> </participant> <performingOrganization> <identifier> <system value="http://myhospital/NamingSystem/departments"/> <value value="CARD_INTERMEDIATE_CARE"/> </identifier> </performingOrganization> <requestingOrganization> <identifier> <system value="http://myhospital/NamingSystem/departments"/> <value value="CARD_U1"/> </identifier> </requestingOrganization> <quantity> <value value="1"/> </quantity> <factorOverride value="0.8"/> <priceOverride> <value value="40"/> <unit value="EUR"/> <system value="urn:iso:std:iso:4217"/> <code value="EUR"/> </priceOverride> <overrideReason value="Patient is Cardiologist's golf buddy, so he gets a 20% discount!"/> <enterer> <reference value="Practitioner/example"/> </enterer> <enteredDate value="2017-01-25T23:55:04+01:00"/> <reason> <coding> <system value="http://hl7.org/fhir/sid/icd-10"/> <code value="123456"/> <display value="DIAG-1"/> </coding> </reason> <service> <reference value="Procedure/example"/> </service> <account> <reference value="Account/example"/> </account> <note> <authorReference> <reference value="Practitioner/example"/> </authorReference> <time value="2017-01-25T23:55:04+01:00"/> <text value="The code is only applicable for periods longer than 4h"/> </note> </ChargeItem>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.