This page is part of the FHIR Specification (v3.5a.0: R4 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
| Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Simple Weight Example
@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Observation/example> a fhir:Observation;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "example"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span>(Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'vital-signs' = 'Vital Signs', given as 'Vital Signs'})</span></p><p><b>code</b>: Body Weight <span>(Details : {LOINC code '29463-7' = 'Body weight', given as 'Body Weight'}; {LOINC code '3141-9' = 'Body weight Measured', given as 'Body weight Measured'}; {SNOMED CT code '27113001' = 'Body weight', given as 'Body weight'}; {http://acme.org/devices/clinical-codes code 'body-weight' = 'body-weight', given as 'Body Weight'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>encounter</b>: <a>Encounter/example</a></p><p><b>effective</b>: 28/03/2016</p><p><b>value</b>: 185 lbs<span> (Details: UCUM code [lb_av] = 'lb_av')</span></p></div>"
];
fhir:Observation.status [ fhir:value "final"];
fhir:Observation.category [
fhir:index 0;
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/observation-category" ];
fhir:Coding.code [ fhir:value "vital-signs" ];
fhir:Coding.display [ fhir:value "Vital Signs" ]
]
];
fhir:Observation.code [
fhir:CodeableConcept.coding [
fhir:index 0;
a loinc:29463-7;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "29463-7" ];
fhir:Coding.display [ fhir:value "Body Weight" ]
], [
fhir:index 1;
a loinc:3141-9;
fhir:Coding.system [ fhir:value "http://loinc.org" ];
fhir:Coding.code [ fhir:value "3141-9" ];
fhir:Coding.display [ fhir:value "Body weight Measured" ]
], [
fhir:index 2;
a sct:27113001;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "27113001" ];
fhir:Coding.display [ fhir:value "Body weight" ]
], [
fhir:index 3;
fhir:Coding.system [ fhir:value "http://acme.org/devices/clinical-codes" ];
fhir:Coding.code [ fhir:value "body-weight" ];
fhir:Coding.display [ fhir:value "Body Weight" ]
]
];
fhir:Observation.subject [
fhir:link <http://hl7.org/fhir/Patient/example>;
fhir:Reference.reference [ fhir:value "Patient/example" ]
];
fhir:Observation.encounter [
fhir:link <http://hl7.org/fhir/Encounter/example>;
fhir:Reference.reference [ fhir:value "Encounter/example" ]
];
fhir:Observation.effectiveDateTime [ fhir:value "2016-03-28"^^xsd:date];
fhir:Observation.valueQuantity [
fhir:Quantity.value [ fhir:value "185"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "lbs" ];
fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
fhir:Quantity.code [ fhir:value "[lb_av]" ]
] .
<http://hl7.org/fhir/Patient/example> a fhir:Patient .
<http://hl7.org/fhir/Encounter/example> a fhir:Encounter .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Observation/example.ttl> a owl:Ontology;
owl:imports fhir:fhir.ttl;
owl:versionIRI <http://build.fhir.org/Observation/example.ttl> .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.