This page is part of the FHIR Specification (v3.5a.0: R4 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
| Pharmacy Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Not linked to any defined compartments |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Subcutaneous injection Example - Manufactured Product - Novolog
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Medication/med0307> a fhir:Medication;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "med0307"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: med0307</p><p><b>contained</b>: </p><p><b>code</b>: Novolog 100u/ml <span>(Details : {http://hl7.org/fhir/sid/ndc code '0169-7501-11' = '0169-7501-11', given as 'Novolog 100u/ml'})</span></p><p><b>manufacturer</b>: id: org3; name: Novo Nordisk</p><p><b>form</b>: Injection solution (qualifier value) <span>(Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection solution (qualifier value)'})</span></p><h3>Ingredients</h3><table><tr><td>-</td><td><b>Item[x]</b></td><td><b>Amount</b></td></tr><tr><td>*</td><td>Insulin Aspart (substance) <span>(Details : {SNOMED CT code '325072002' = 'Insulin aspart', given as 'Insulin Aspart (substance)'})</span></td><td>100 U<span> (Details: UCUM code U = 'U')</span>/1 mL<span> (Details: UCUM code mL = 'mL')</span></td></tr></table><h3>Batches</h3><table><tr><td>-</td><td><b>LotNumber</b></td><td><b>ExpirationDate</b></td></tr><tr><td>*</td><td>12345</td><td>31/10/2019</td></tr></table></div>"
];
fhir:DomainResource.contained [
a fhir:Organization;
fhir:index 0;
fhir:Resource.id [ fhir:value "org3" ];
fhir:Organization.name [ fhir:value "Novo Nordisk" ]
];
fhir:Medication.code [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
fhir:Coding.code [ fhir:value "0169-7501-11" ];
fhir:Coding.display [ fhir:value "Novolog 100u/ml" ]
]
];
fhir:Medication.manufacturer [
fhir:Reference.reference [ fhir:value "#org3" ]
];
fhir:Medication.form [
fhir:CodeableConcept.coding [
fhir:index 0;
a sct:385219001;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "385219001" ];
fhir:Coding.display [ fhir:value "Injection solution (qualifier value)" ]
]
];
fhir:Medication.ingredient [
fhir:index 0;
fhir:Medication.ingredient.itemCodeableConcept [
fhir:CodeableConcept.coding [
fhir:index 0;
a sct:325072002;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "325072002" ];
fhir:Coding.display [ fhir:value "Insulin Aspart (substance)" ]
]
];
fhir:Medication.ingredient.amount [
fhir:Ratio.numerator [
fhir:Quantity.value [ fhir:value "100"^^xsd:decimal ];
fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
fhir:Quantity.code [ fhir:value "U" ]
];
fhir:Ratio.denominator [
fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ];
fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
fhir:Quantity.code [ fhir:value "mL" ]
]
]
];
fhir:Medication.batch [
fhir:Medication.batch.lotNumber [ fhir:value "12345" ];
fhir:Medication.batch.expirationDate [ fhir:value "2019-10-31"^^xsd:date ]
] .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Medication/med0307.ttl> a owl:Ontology;
owl:imports fhir:fhir.ttl;
owl:versionIRI <http://build.fhir.org/Medication/med0307.ttl> .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.