HL7 Electronic Health Record System Functional Model, Release 2.1.1
2.1.1 - Normative
This page is part of the HL7 Electronic Health Record System Functional Model, Release 2.1.1 (v2.1.1: Normative 1 - Normative) based on FHIR (HL7® FHIR® Standard) v5.0.0. This is the current published version. For a full list of available versions, see the Directory of published versions
| Official URL: http://hl7.org/ehrs/uv/ehrsfmr2/Requirements/EHRSFMR2-TI.2.1.3 | Version: 2.1.1 | ||||
| Standards status: Normative | Computable Name: TI_2_1_3_System_Audit_Triggers | ||||
Manage System Audit Triggers
System Audit Triggers are designed to capture system related events, both routine and exceptional, including key metadata (who, what, when, where, why).
| TI.2.1.3#01 | SHOULD |
The system SHOULD provide the ability to log system maintenance events for loading new versions of, or changes to, the clinical system. |
| TI.2.1.3#02 | SHOULD |
The system SHOULD provide the ability to store system maintenance events for loading new versions of codes and knowledge bases. |
| TI.2.1.3#03 | SHOULD |
The system SHOULD provide the ability to log system maintenance events for creating and restoring of backup. |
| TI.2.1.3#04 | SHOULD |
The system SHOULD provide the ability to audit events in the case of detection of corrupt or dirty data. |
| TI.2.1.3#05 | SHALL |
The system SHALL provide the ability to audit the access and usage of systems, data, and organizational resources. |
| TI.2.1.3#06 | SHALL |
The system SHALL provide the ability to log system events at the hardware and software architecture level. |
| TI.2.1.3#07 | SHALL |
The system SHALL provide the ability to log system maintenance events for entry to, and exit from, the EHR system. |
| TI.2.1.3#08 | SHALL |
The system SHALL provide the ability to log system maintenance events for remote access connections including those for system support and maintenance activities for security and access purposes. |