Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Example ServiceRequest/di (JSON)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

CT Scan order

{
  "resourceType" : "ServiceRequest",
  "id" : "di",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: ServiceRequest</b><a name=\"di\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource ServiceRequest &quot;di&quot; </p></div><p><b>status</b>: <span title=\" \t&lt;extension url=&quot;http://hl7.org/fhir/StructureDefinition/bodysitecode&quot;&gt;\n\t\t&lt;valueCodeableConcept&gt;\n\t\t\t&lt;coding&gt;\n\t\t\t\t&lt;system value=&quot;http://snomed.info/sct&quot;/&gt;\n\t\t\t\t&lt;code value=&quot;51185008&quot;/&gt;\n\t\t\t\t&lt;display value=&quot;Thoracic structure&quot;/&gt;\n\t\t\t&lt;/coding&gt;\n\t\t&lt;/valueCodeableConcept&gt;\n&lt;/extension&gt;\n\t \">active</span></p><p><b>intent</b>: original-order</p><h3>Codes</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Chest CT <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#24627-2)</span></td></tr></table><p><b>subject</b>: <a href=\"patient-example-dicom.html\">Patient/dicom</a> &quot; MINT_TEST&quot;</p><p><b>occurrence</b>: 2013-05-08T09:33:27+07:00</p><p><b>requester</b>: <a href=\"practitioner-example.html\">Practitioner/example: Dr. Adam Careful</a> &quot;Adam CAREFUL&quot;</p><h3>Reasons</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Check for metastatic disease <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table></div>"
  },
  "status" : "active",
  "intent" : "original-order",
  "code" : {
    "concept" : {
      "coding" : [{
        "system" : "http://loinc.org",
        "code" : "24627-2"
      }],
      "text" : "Chest CT"
    }
  },
  "subject" : {
    "reference" : "Patient/dicom"
  },
  "occurrenceDateTime" : "2013-05-08T09:33:27+07:00",
  "requester" : {
    "reference" : "Practitioner/example",
    "display" : "Dr. Adam Careful"
  },
  "reason" : [{
    "concept" : {
      "text" : "Check for metastatic disease"
    }
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.