Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Example Observation/satO2 (Turtle)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw Turtle (+ also see Turtle/RDF Format Specification)

Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile)

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <https://loinc.org/rdf/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

[a fhir:Observation ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "satO2"] ; # 
  fhir:meta [
     fhir:profile ( [
       fhir:v "http://hl7.org/fhir/StructureDefinition/vitalsigns"^^xsd:anyURI ;
       fhir:link <http://hl7.org/fhir/StructureDefinition/vitalsigns>
     ] )
  ] ; # 
  fhir:text [
     fhir:status [ fhir:v "generated" ] ;
     fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"satO2\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation &quot;satO2&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"vitalsigns.html\">Vital Signs Profile</a></p></div><p><b>identifier</b>: id: o1223435-10</p><p><b>partOf</b>: <a href=\"procedure-example-ob.html\">Procedure/ob</a></p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Oxygen saturation in Arterial blood <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#2708-6; <a href=\"https://loinc.org/\">LOINC</a>#59408-5 &quot;Oxygen saturation in Arterial blood by Pulse oximetry&quot;; <a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#150456 &quot;MDC_PULS_OXIM_SAT_O2&quot;)</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> &quot;Peter CHALMERS&quot;</p><p><b>effective</b>: 2014-12-05T09:30:10+01:00</p><p><b>value</b>: 95 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></p><p><b>interpretation</b>: Normal (applies to non-numeric results) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#N &quot;Normal&quot;)</span></p><p><b>device</b>: <a href=\"devicemetric-example.html\">DeviceMetric/example</a></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></td><td>99 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code % = '%')</span></td></tr></table></div>"
  ] ; # 
  fhir:identifier ( [
     fhir:system [ fhir:v "http://goodcare.org/observation/id"^^xsd:anyURI ] ;
     fhir:value [ fhir:v "o1223435-10" ]
  ] ) ; # 
  fhir:partOf ( [
     fhir:reference [ fhir:v "Procedure/ob" ]
  ] ) ; # 
  fhir:status [ fhir:v "final"] ; # 
  fhir:category ( [
     fhir:coding ( [
       fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/observation-category"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "vital-signs" ] ;
       fhir:display [ fhir:v "Vital Signs" ]
     ] ) ;
     fhir:text [ fhir:v "Vital Signs" ]
  ] ) ; # 
  fhir:code [
     fhir:coding ( [
       a loinc:2708-6 ;
       fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "2708-6" ] ; #    LOINC   
       fhir:display [ fhir:v "Oxygen saturation in Arterial blood" ]
     ] [
       a loinc:59408-5 ;
       fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "59408-5" ] ; #    LOINC   
       fhir:display [ fhir:v "Oxygen saturation in Arterial blood by Pulse oximetry" ]
     ] [
       fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "150456" ] ; #       mdc      
       fhir:display [ fhir:v "MDC_PULS_OXIM_SAT_O2" ]
     ] )
  ] ; # 
  fhir:subject [
     fhir:reference [ fhir:v "Patient/example" ]
  ] ; # 
  fhir:effective [ fhir:v "2014-12-05T09:30:10+01:00"^^xsd:dateTime] ; # 
  fhir:value [
     a fhir:Quantity ;
     fhir:value [ fhir:v "95"^^xsd:decimal ] ;
     fhir:unit [ fhir:v "%" ] ;
     fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
     fhir:code [ fhir:v "%" ]
  ] ; # 
  fhir:interpretation ( [
     fhir:coding ( [
       fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "N" ] ;
       fhir:display [ fhir:v "Normal" ]
     ] ) ;
     fhir:text [ fhir:v "Normal (applies to non-numeric results)" ]
  ] ) ; # 
  fhir:device [
     fhir:reference [ fhir:v "DeviceMetric/example" ]
  ] ; # 
  fhir:referenceRange ( [
     fhir:low [
       fhir:value [ fhir:v "90"^^xsd:decimal ] ;
       fhir:unit [ fhir:v "%" ] ;
       fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "%" ]
     ] ;
     fhir:high [
       fhir:value [ fhir:v "99"^^xsd:decimal ] ;
       fhir:unit [ fhir:v "%" ] ;
       fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "%" ]
     ]
  ] )] . # 

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.