Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
If the element is present, it must have either a @value, an @id, or extensions
Identifiers for the ImagingStudy such as DICOM Study Instance UID.
The current state of the ImagingStudy resource. This is not the status of any ServiceRequest or Task resources associated with the ImagingStudy.
A list of all the distinct values of series.modality. This may include both acquisition and non-acquisition modalities.
The subject, typically a patient, of the imaging study.
The healthcare event (e.g. a patient and healthcare provider interaction) during which this ImagingStudy is made.
Date and time the study started.
A list of the diagnostic requests that resulted in this imaging study being performed.
A larger event of which this particular ImagingStudy is a component or step. For example, an ImagingStudy as part of a procedure.
The requesting/referring physician.
The network service providing access (e.g., query, view, or retrieval) for the study. See implementation notes for information about using DICOM endpoints. A study-level endpoint applies to each series in the study, unless overridden by a series-level endpoint with the same Endpoint.connectionType.
Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present.
Number of SOP Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
This field corresponds to the DICOM Procedure Code Sequence (0008,1032). This is different from the FHIR Procedure resource that may include the ImagingStudy.
The principal physical location where the ImagingStudy was performed.
Description of clinical condition indicating why the ImagingStudy was requested, and/or Indicates another resource whose existence justifies this Study.
Per the recommended DICOM mapping, this element is derived from the Study Description attribute (0008,1030). Observations or findings about the imaging study should be recorded in another resource, e.g. Observation, and not in this element.
The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed.
Each study has one or more series of images or other content.
Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
The DICOM Series Instance UID for the series.
The numeric identifier of this series in the study.
The distinct modality for this series. This may include both acquisition and non-acquisition modalities.
A description of the series.
Number of SOP Instances in the Study. The value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present.
The network service providing access (e.g., query, view, or retrieval) for this series. See implementation notes for information about using DICOM endpoints. A series-level endpoint, if present, has precedence over a study-level endpoint with the same Endpoint.connectionType.
The anatomic structures examined. See DICOM Part 16 Annex L (http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_L.html) for DICOM to SNOMED-CT mappings. The bodySite may indicate the laterality of body part imaged; if so, it shall be consistent with any content of ImagingStudy.series.laterality.
The laterality of the (possibly paired) anatomic structures examined. E.g., the left knee, both lungs, or unpaired abdomen. If present, shall be consistent with any laterality information indicated in ImagingStudy.series.bodySite.
The specimen imaged, e.g., for whole slide imaging of a biopsy.
The date and time the series was started.
Indicates who or what performed the series and how they were involved.
A single SOP instance within the series, e.g. an image, or presentation state.
Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
Distinguishes the type of involvement of the performer in the series.
Indicates who or what performed the series.
Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
The DICOM SOP Instance UID for this image or other DICOM content.
DICOM instance type.
The number of instance in the series.
The description of the instance.
Registered
Available
Cancelled
Entered in Error
Unknown
If the element is present, it must have either a @value, an @id, or extensions