Release 5

This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Example ImagingStudy/example-xr (JSON)

Imaging Integration Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Patient

Raw JSON (canonical form + also see JSON Format Specification)

Example XR imaging study with full elements

{
  "resourceType" : "ImagingStudy",
  "id" : "example-xr",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">XR Wrist 3+ Views. John Smith (MRN: 09236). Accession: W12342398. Performed: 2017-01-01.\n       1 series, 2 images.</div>"
  },
  "identifier" : [{
    "use" : "official",
    "system" : "urn:dicom:uid",
    "value" : "urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430046"
  },
  {
    "use" : "secondary",
    "value" : "55551234",
    "assigner" : {
      "reference" : "Organization/dicom-organization"
    }
  }],
  "status" : "available",
  "modality" : [{
    "coding" : [{
      "system" : "http://dicom.nema.org/resources/ontology/DCM",
      "code" : "DX"
    }]
  }],
  "subject" : {
    "reference" : "Patient/dicom"
  },
  "encounter" : {
    "reference" : "Encounter/example"
  },
  "started" : "2017-01-01T11:01:20+03:00",
  "basedOn" : [{
    "type" : "ServiceRequest",
    "identifier" : {
      "type" : {
        "coding" : [{
          "system" : "http://terminology.hl7.org/CodeSystem/v2-0203",
          "code" : "ACSN"
        }]
      },
      "value" : "W12342398",
      "assigner" : {
        "reference" : "Organization/dicom-organization"
      }
    }
  },
  {
    "reference" : "ServiceRequest/example"
  }],
  "referrer" : {
    "reference" : "Practitioner/example"
  },
  "endpoint" : [{
    "reference" : "Endpoint/example-wadors"
  }],
  "numberOfSeries" : 1,
  "numberOfInstances" : 2,
  "procedure" : [{
    "reference" : {
      "reference" : "Procedure/example"
    }
  },
  {
    "concept" : {
      "coding" : [{
        "system" : "http://www.radlex.org",
        "code" : "RPID2589",
        "display" : "XR Wrist 3+ Views"
      }],
      "text" : "XR Wrist 3+ Views"
    }
  }],
  "reason" : [{
    "concept" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "357009",
        "display" : "Closed fracture of trapezoidal bone of wrist"
      }]
    }
  }],
  "note" : [{
    "text" : "XR Wrist 3+ Views"
  }],
  "series" : [{
    "uid" : "2.16.124.113543.6003.1154777499.30246.19789.3503430045.1",
    "number" : 3,
    "modality" : {
      "coding" : [{
        "system" : "http://dicom.nema.org/resources/ontology/DCM",
        "code" : "DX"
      }]
    },
    "description" : "XR Wrist 3+ Views",
    "numberOfInstances" : 2,
    "endpoint" : [{
      "reference" : "Endpoint/example-wadors"
    }],
    "bodySite" : {
      "concept" : {
        "coding" : [{
          "system" : "http://snomed.info/sct",
          "code" : "T-15460",
          "display" : "Wrist Joint"
        }]
      }
    },
    "laterality" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "419161000",
        "display" : "Unilateral left"
      }]
    },
    "started" : "2011-01-01T11:01:20+03:00",
    "performer" : [{
      "function" : {
        "coding" : [{
          "system" : "http://terminology.hl7.org/CodeSystem/v3-ParticipationType",
          "code" : "PRF"
        }]
      },
      "actor" : {
        "reference" : "Practitioner/example"
      }
    }],
    "instance" : [{
      "uid" : "2.16.124.113543.6003.1154777499.30246.19789.3503430045.1.1",
      "sopClass" : {
        "system" : "urn:ietf:rfc:3986",
        "code" : "urn:oid:1.2.840.10008.5.1.4.1.1.2"
      },
      "number" : 1,
      "title" : "PA VIEW"
    },
    {
      "uid" : "2.16.124.113543.6003.1154777499.30246.19789.3503430045.1.2",
      "sopClass" : {
        "system" : "urn:ietf:rfc:3986",
        "code" : "urn:oid:1.2.840.10008.5.1.4.1.1.2"
      },
      "number" : 2,
      "title" : "LL VIEW"
    }]
  }]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.