Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw Turtle (+ also see Turtle/RDF Format Specification)
PhilipsThermometer
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- [a fhir:Device ; fhir:nodeRole fhir:treeRoot ; fhir:id [ fhir:v "PhilipsThermometer"] ; # fhir:text [ fhir:status [ fhir:v "generated" ] ; fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"PhilipsThermometer\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "PhilipsThermometer" </p></div><p><b>identifier</b>: System Identifier: 1C-87-74-FF-FE-00-EC-20, Bluetooth Address: 1C-87-74-00-EC-20</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>31368092380192</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)31368092380192(21)162502000528</td><td>unknown</td></tr></table><p><b>manufacturer</b>: Philips</p><p><b>serialNumber</b>: 162502000528</p><h3>Names</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Philips ear thermometer</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: DL8740</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: 1.60</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 1.50</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 1.40</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></p><p><b>value</b>: 5.1</p></blockquote><h3>ConformsTos</h3><table class=\"grid\"><tr><td>-</td><td><b>Specification</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528392)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 32776 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#32776)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.1)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>" ] ; # fhir:identifier ( [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ; fhir:code [ fhir:v "SYSID" ] ; fhir:display [ fhir:v "System Identifier" ] ] ) ] ; fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ; fhir:value [ fhir:v "1C-87-74-FF-FE-00-EC-20" ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ; fhir:code [ fhir:v "BTMAC" ] ; fhir:display [ fhir:v "Bluetooth Address" ] ] ) ] ; fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48"^^xsd:anyURI ] ; fhir:value [ fhir:v "1C-87-74-00-EC-20" ] ] ) ; # fhir:udiCarrier ( [ fhir:deviceIdentifier [ fhir:v "31368092380192" ] ; fhir:issuer [ fhir:v "http://hl7.org/fhir/NamingSystem/gs1-di"^^xsd:anyURI ] ; fhir:jurisdiction [ fhir:v "http://hl7.org/fhir/NamingSystem/fda-udi"^^xsd:anyURI ] ; fhir:carrierHRF [ fhir:v "(01)31368092380192(21)162502000528" ] ; fhir:entryType [ fhir:v "unknown" ] ] ) ; # fhir:manufacturer [ fhir:v "Philips"] ; # fhir:serialNumber [ fhir:v "162502000528"] ; # fhir:name ( [ fhir:value [ fhir:v "Philips ear thermometer" ] ; fhir:type [ fhir:v "user-friendly-name" ] ] ) ; # fhir:modelNumber [ fhir:v "DL8740"] ; # fhir:type ( [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "65573" ] ; fhir:display [ fhir:v "MDC_MOC_VMS_MDS_SIMP" ] ] ) ; fhir:text [ fhir:v "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" ] ] ) ; # fhir:version ( [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "531976" ] ] ) ; fhir:text [ fhir:v "MDC_ID_PROD_SPEC_FW: Firmware revision" ] ] ; fhir:value [ fhir:v "1.60" ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "531975" ] ] ) ; fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Software revision" ] ] ; fhir:value [ fhir:v "1.50" ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "531974" ] ] ) ; fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Hardware revision" ] ] ; fhir:value [ fhir:v "1.40" ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "532352" ] ] ) ; fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ] ] ; fhir:value [ fhir:v "5.1" ] ] ) ; # fhir:conformsTo ( [ fhir:specification [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "528392" ] ] ) ; fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_TEMP: Thermometer" ] ] ; fhir:version [ fhir:v "1" ] ] ) ; # fhir:property ( [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "532353" ] ] ) ; fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" ] ] ; fhir:value [ a fhir:CodeableConcept ; fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaPAN"^^xsd:anyURI ] ; fhir:code [ fhir:v "32776" ] ] ) ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ; fhir:code [ fhir:v "532354.0" ] ] ) ; fhir:text [ fhir:v "regulation-status" ] ] ; fhir:value [ a fhir:CodeableConcept ; fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ; fhir:code [ fhir:v "N" ] ] ) ; fhir:text [ fhir:v "Device is Regulated" ] ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "68220" ] ] ) ; fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ] ] ; fhir:value [ a fhir:CodeableConcept ; fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "532224" ] ] ) ; fhir:text [ fhir:v "MDC_TIME_SYNC_NONE: No time synchronization" ] ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ; fhir:code [ fhir:v "68219.0" ] ] ) ; fhir:text [ fhir:v "mds-time-capab-real-time-clock" ] ] ; fhir:value [ a fhir:CodeableConcept ; fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ; fhir:code [ fhir:v "Y" ] ] ) ; fhir:text [ fhir:v "real time clock supported" ] ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ; fhir:code [ fhir:v "68219.1" ] ] ) ; fhir:text [ fhir:v "mds-time-capab-set-clock" ] ] ; fhir:value [ a fhir:CodeableConcept ; fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ; fhir:code [ fhir:v "Y" ] ] ) ; fhir:text [ fhir:v "setting the time supported" ] ] ] )] . # # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change