Release 5

Publish-box (todo)

Example Device/PhilipsThermometer (Turtle)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw Turtle (+ also see Turtle/RDF Format Specification)

PhilipsThermometer

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

[a fhir:Device ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "PhilipsThermometer"] ; # 
  fhir:text [
     fhir:status [ fhir:v "generated" ] ;
     fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"PhilipsThermometer\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;PhilipsThermometer&quot; </p></div><p><b>identifier</b>: System Identifier: 1C-87-74-FF-FE-00-EC-20, Bluetooth Address: 1C-87-74-00-EC-20</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>31368092380192</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)31368092380192(21)162502000528</td><td>unknown</td></tr></table><p><b>manufacturer</b>: Philips</p><p><b>serialNumber</b>: 162502000528</p><h3>Names</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Philips ear thermometer</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: DL8740</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: 1.60</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 1.50</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 1.40</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352)</span></p><p><b>value</b>: 5.1</p></blockquote><h3>ConformsTos</h3><table class=\"grid\"><tr><td>-</td><td><b>Specification</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528392)</span></td><td>1</td></tr></table><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>value</b>: 32776 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ContinuaPAN#32776)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#532354.0)</span></p><p><b>value</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>value</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.0)</span></p><p><b>value</b>: real time clock supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (ASN1ToHL7#68219.1)</span></p><p><b>value</b>: setting the time supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (v2-0136#Y)</span></p></blockquote></div>"
  ] ; # 
  fhir:identifier ( [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "SYSID" ] ;
         fhir:display [ fhir:v "System Identifier" ]
       ] )
     ] ;
     fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ;
     fhir:value [ fhir:v "1C-87-74-FF-FE-00-EC-20" ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "BTMAC" ] ;
         fhir:display [ fhir:v "Bluetooth Address" ]
       ] )
     ] ;
     fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48"^^xsd:anyURI ] ;
     fhir:value [ fhir:v "1C-87-74-00-EC-20" ]
  ] ) ; # 
  fhir:udiCarrier ( [
     fhir:deviceIdentifier [ fhir:v "31368092380192" ] ;
     fhir:issuer [ fhir:v "http://hl7.org/fhir/NamingSystem/gs1-di"^^xsd:anyURI ] ;
     fhir:jurisdiction [ fhir:v "http://hl7.org/fhir/NamingSystem/fda-udi"^^xsd:anyURI ] ;
     fhir:carrierHRF [ fhir:v "(01)31368092380192(21)162502000528" ] ;
     fhir:entryType [ fhir:v "unknown" ]
  ] ) ; # 
  fhir:manufacturer [ fhir:v "Philips"] ; # 
  fhir:serialNumber [ fhir:v "162502000528"] ; # 
  fhir:name ( [
     fhir:value [ fhir:v "Philips ear thermometer" ] ;
     fhir:type [ fhir:v "user-friendly-name" ]
  ] ) ; # 
  fhir:modelNumber [ fhir:v "DL8740"] ; # 
  fhir:type ( [
     fhir:coding ( [
       fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "65573" ] ;
       fhir:display [ fhir:v "MDC_MOC_VMS_MDS_SIMP" ]
     ] ) ;
     fhir:text [ fhir:v "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" ]
  ] ) ; # 
  fhir:version ( [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "531976" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_ID_PROD_SPEC_FW: Firmware revision" ]
     ] ;
     fhir:value [ fhir:v "1.60" ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "531975" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Software revision" ]
     ] ;
     fhir:value [ fhir:v "1.50" ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "531974" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Hardware revision" ]
     ] ;
     fhir:value [ fhir:v "1.40" ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532352" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ]
     ] ;
     fhir:value [ fhir:v "5.1" ]
  ] ) ; # 
  fhir:conformsTo ( [
     fhir:specification [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "528392" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_TEMP: Thermometer" ]
     ] ;
     fhir:version [ fhir:v "1" ]
  ] ) ; # 
  fhir:property ( [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532353" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaPAN"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "32776" ]
       ] )
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532354.0" ]
       ] ) ;
       fhir:text [ fhir:v "regulation-status" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "N" ]
       ] ) ;
       fhir:text [ fhir:v "Device is Regulated" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68220" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "532224" ]
       ] ) ;
       fhir:text [ fhir:v "MDC_TIME_SYNC_NONE: No time synchronization" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68219.0" ]
       ] ) ;
       fhir:text [ fhir:v "mds-time-capab-real-time-clock" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "Y" ]
       ] ) ;
       fhir:text [ fhir:v "real time clock supported" ]
     ]
  ] [
     fhir:type [
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "68219.1" ]
       ] ) ;
       fhir:text [ fhir:v "mds-time-capab-set-clock" ]
     ] ;
     fhir:value [
       a fhir:CodeableConcept ;
       fhir:coding ( [
         fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
         fhir:code [ fhir:v "Y" ]
       ] ) ;
       fhir:text [ fhir:v "setting the time supported" ]
     ]
  ] )] . # 

# -------------------------------------------------------------------------------------