Release 5

Publish-box (todo)

Example Device/KinsaThermometer (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

KinsaThermometer (id = "KinsaThermometer")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">
<id value="KinsaThermometer"/>  
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="KinsaThermometer"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;KinsaThermometer&quot; </p> </div> <p> <b> identifier</b> : System Identifier: 00-00-52-49-20-45-4C-42, Bluetooth Address: 10-CE-A9-80-14-66</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 18479793050726</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1-di">http://hl7.org/fhir/NamingSystem/gs1-di</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> (01)18479793050726(21)1i9JfKh</td> <td> unknown</td> </tr> </table> <p> <b> manufacturer</b> : Kinsa</p> <p> <b> serialNumber</b> : 1i9JfKh</p> <h3> Names</h3> <table class="grid"><tr> <td> -</td> <td> <b> Value</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> KS_1i9JfKh</td> <td> user-friendly-name</td> </tr> </table> <p> <b> modelNumber</b> : KS_1i9JfKh</p> <p> <b> type</b> : MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #65573 &quot;MDC_MOC_VMS_MDS_SIMP&quot;)</span> </p> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_FW: Firmware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531976)</span> </p> <p> <b> value</b> : 1.00</p> </blockquote> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_SW: Software revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531975)</span> </p> <p> <b> value</b> : V2.19</p> </blockquote> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_SW: Hardware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531974)</span> </p> <p> <b> value</b> : 1.00</p> </blockquote> <h3> ConformsTos</h3> <table class="grid"><tr> <td> -</td> <td> <b> Specification</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td> *</td> <td> MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528392)</span> </td> <td> 1</td> </tr> </table> <h3> Properties</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> Value[x]</b> </td> </tr> <tr> <td> *</td> <td> MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #68220)</span> </td> <td> MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532224)</span> </td> </tr> </table> </div> </text> <identifier> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> 
        <code value="SYSID"/> 
        <display value="System Identifier"/> 
      </coding> 
    </type> 
    <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> 
    <value value="00-00-52-49-20-45-4C-42"/> 
  </identifier> 
  <identifier> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> 
        <code value="BTMAC"/> 
        <display value="Bluetooth Address"/> 
      </coding> 
    </type> 
    <system value="http://hl7.org/fhir/sid/eui-48"/> 
    <value value="10-CE-A9-80-14-66"/> 
  </identifier> 
  <udiCarrier> 
    <deviceIdentifier value="18479793050726"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierHRF value="(01)18479793050726(21)1i9JfKh"/> 
    <entryType value="unknown"/> 
  </udiCarrier> 
  <manufacturer value="Kinsa"/> 
  <serialNumber value="1i9JfKh"/> 
  <name> 
    <value value="KS_1i9JfKh"/> 
    <type value="user-friendly-name"/> 
  </name> 
  <modelNumber value="KS_1i9JfKh"/> 
  <type> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="65573"/> 
      <display value="MDC_MOC_VMS_MDS_SIMP"/> 
    </coding> 
    <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> 
  </type> 
  <version> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="531976"/> 
      </coding> 
      <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/> 
    </type> 
    <value value="1.00"/> 
  </version> 
  <version> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="531975"/> 
      </coding> 
      <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> 
    </type> 
    <value value="V2.19"/> 
  </version> 
  <version> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="531974"/> 
      </coding> 
      <text value="MDC_ID_PROD_SPEC_SW: Hardware revision"/> 
    </type> 
    <value value="1.00"/> 
  </version> 
  <conformsTo> 
    <specification> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="528392"/> 
      </coding> 
      <text value="MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"/> 
    </specification> 
    <version value="1"/> 
  </conformsTo> 
  <property> 
    <type> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="68220"/> 
      </coding> 
      <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> 
    </type> 
    <valueCodeableConcept> 
      <coding> 
        <system value="urn:iso:std:iso:11073:10101"/> 
        <code value="532224"/> 
      </coding> 
      <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> 
    </valueCodeableConcept> 
  </property> 
  </Device> 