Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
AND20601BPMonitor (id = "and20601bpmonitor")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="and20601bpmonitor"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="and20601bpmonitor"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "and20601bpmonitor" </p> </div> <p> <b> identifier</b> : System Identifier: 00-09-1F-FF-FE-80-07-3A, Bluetooth Address: 00-09-1F-80-07-3A</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 39183189818</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1-di">http://hl7.org/fhir/NamingSystem/gs1-di</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> (01)39183189818(21)5091100966</td> <td> unknown</td> </tr> </table> <p> <b> manufacturer</b> : A&D Medical</p> <p> <b> serialNumber</b> : 5091100966</p> <h3> Names</h3> <table class="grid"><tr> <td> -</td> <td> <b> Value</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> AND BP UA-767PBT-C</td> <td> user-friendly-name</td> </tr> </table> <p> <b> modelNumber</b> : UA-767PBT-C</p> <p> <b> type</b> : MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #65573 "MDC_MOC_VMS_MDS_SIMP")</span> </p> <h3> Versions</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> Value</b> </td> </tr> <tr> <td> *</td> <td> MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532352)</span> </td> <td> 1.0</td> </tr> </table> <h3> ConformsTos</h3> <table class="grid"><tr> <td> -</td> <td> <b> Specification</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td> *</td> <td> MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528391)</span> </td> <td> 1</td> </tr> </table> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532353)</span> </p> <p> <b> value</b> : 7 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ContinuaPAN#7)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#532354.0)</span> </p> <p> <b> value</b> : Device is Regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#N)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #68220)</span> </p> <p> <b> value</b> : MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532224)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-real-time-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.0)</span> </p> <p> <b> value</b> : real time clock supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-capab-set-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.1)</span> </p> <p> <b> value</b> : setting the time supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> <blockquote> <p> <b> property</b> </p> <p> <b> type</b> : mds-time-mgr-set-time <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (ASN1ToHL7#68219.11)</span> </p> <p> <b> value</b> : manager requested to set the time <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (v2-0136#Y)</span> </p> </blockquote> </div> </text> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="00-09-1F-FF-FE-80-07-3A"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="00-09-1F-80-07-3A"/> </identifier> <udiCarrier> <deviceIdentifier value="39183189818"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)39183189818(21)5091100966"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="A&D Medical"/> <serialNumber value="5091100966"/> <name> <value value="AND BP UA-767PBT-C"/> <type value="user-friendly-name"/> </name> <modelNumber value="UA-767PBT-C"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532352"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/> </type> <value value="1.0"/> </version> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528391"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"/> </specification> <version value="1"/> </conformsTo> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532353"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaPAN"/> <code value="7"/> </coding> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="532354.0"/> <display value="regulation-status"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="N"/> </coding> <text value="Device is Regulated"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.0"/> </coding> <text value="mds-time-capab-real-time-clock"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="real time clock supported"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.1"/> </coding> <text value="mds-time-capab-set-clock"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="setting the time supported"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.11"/> </coding> <text value="mds-time-mgr-set-time"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="manager requested to set the time"/> </valueCodeableConcept> </property> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change